Siemens SIRIUS 3RK4353-3NR58-1BA0 reversing motor starter, MCU controlled on-site, IP55, 10 A at 400 V AC-3, Trip Class 10, 3-pole, 145 x 182 x 220 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RK4353-3NR58-1BA0 — Identification
ParameterValue
Product designationmotor starter MCU controlled on site
Main circuit poles3
BrandSIRIUS
Product design / constructionreversing starter
Reference designation (IEC 81346-2)Q
3RK4353-3NR58-1BA0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Overload release setting range (current)7 ... 10 A
Duty / utilization type (IEC 60947-6-2)1
3RK4353-3NR58-1BA0 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz184 ... 253 V
Switching contact typeelectromechanical
3RK4353-3NR58-1BA0 — Communication
ParameterValue
AS-Interface protocol supportNo
3RK4353-3NR58-1BA0 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width182 mm
Height220 mm
Depth145 mm

Product details

Reversing capability in a single enclosure

The 3RK4353-3NR58-1BA0: This SIRIUS reversing starter integrates forward and reverse contactors plus a bimetal overload relay in one IP55 housing, eliminating the need for an external reversing contactor pair and the interlock wiring. The MCU-controlled on-site logic handles the reversing sequence and motor protection locally — no PLC is required for the basic start/stop/reverse functions, though two digital inputs are available for external control signals.

AC-3 motor switching and trip coordination

Supply voltage for the control circuit is 184–253 V at 50 Hz and 196–253 V at 60 Hz. The main motor circuit operates on 340–440 V AC. The unit draws its control power from the line side, so no separate control transformer is needed within that voltage window.

Panel fit and environmental limits

Envelope is 145 mm deep, 182 mm wide, 220 mm tall (-). Ambient operating range is -25 to +35 °C. Above 35 °C the thermal overload must be derated — the bimetal element's trip curve shifts with ambient temperature. The maximum operating frequency is 80 cycles per hour, which governs the start/stop/reverse duty cycle in high-throughput applications.