Siemens 3RT1015-1AB01-ZW96 — Contactors

Siemens 3RT1015-1AB01-ZW96 SIRIUS S00 Contactor, 10A Aux, 3k

MPN3RT1015-1AB01-ZW96

Siemens SIRIUS S00 power contactor, 3RT1015-1AB01-ZW96, screw-type terminals, 24 V 50/60 Hz coil, 10 A auxiliary contact, 3 kW at 400 V AC-3, 4 kW at 690 V AC-3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT1015-1AB01-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-1AB01-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-1AB01-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1015-1AB01-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-1AB01-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-1AB01-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1015-1AB01-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1015-1AB01-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-1AB01-ZW96 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It carries a 24 V 50/60 Hz coil, an instantaneous auxiliary contact rated 10 A at 24 V, and delivers 3 kW at 400 V AC-3 or 4 kW at 690 V AC-3. The screw-type terminals accept 2x (0.5 to 4 mm²) conductors, and the contactor mounts via screw or snap-on onto 35 mm DIN rail per EN 50022.

The S00 frame size (45 mm wide, 57.5 mm high, 72 mm deep) is the smallest SIRIUS contactor footprint — it fits tight DIN-rail layouts where panel space is at a premium. The 10 A auxiliary contact at 24 V covers PLC-level signal switching; the 2 A rating at 60 V and 0.3 A at 220 V show it can handle pilot-duty loads across common control voltages. Motor power ratings of 3 kW at 400 V AC-3 and 4 kW at 690 V AC-3 define the maximum three-phase induction motor it can switch under normal starting duty. For AC-4 (plugging/reversing) at 400 V, the current limit drops to 6.5 A — a key derating factor if the application involves frequent inching or reversing. Short-circuit coordination is specified: with type 2 coordination (limited damage to contactor after fault), use a gL/gG fuse rated 20 A; with type 1 coordination (contactor may need replacement), use 35 A. This matters for selectivity studies and fuse sizing in the feeder circuit.

The 3RT1015-1AB01-ZW96 is a general-purpose power contactor for switching three-phase motors up to 4 kW in conveyors, pumps, fans, compressors, and small machine tools. It also switches resistive loads (AC-1) up to 10 A, making it suitable for heater banks and lighting contactor panels. The IP20 finger-safe terminals on the front and at the connection side mean it can be installed in open control panels without additional shrouding.

Frequently asked questions

What are the key motor power ratings for the 3RT1015-1AB01-ZW96?

It is rated 3 kW at 400 V AC-3 and 4 kW at 690 V AC-3 for three-phase induction motor switching. For AC-4 duty (reversing/plugging) at 400 V, the current limit is 6.5 A.

What is the coil voltage and frequency for this contactor?

The coil is rated 24 V at both 50 Hz and 60 Hz, with an operating range of 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz.

What wire sizes does the screw terminal accept?

The main circuit screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12.

Will the 3RT1015-1AB01-ZW96 drop into a panel designed for the 3RT1016-2AP02?

Both are S00 frame size contactors with the same 45 mm width and DIN-rail mounting, so the physical footprint and rail position are identical. The difference is in coil voltage and auxiliary contact configuration — verify the control circuit voltage and aux contact count match your panel wiring before substituting.

MPN
3RT1015-1AB01-ZW96