Siemens SIRIUS 3RT1015-1AH01-ZW95 Power Contactor, Size S00,

MPN3RT1015-1AH01-ZW95

Siemens SIRIUS 3RT1015-1AH01-ZW95 power contactor, size S00, 24 VDC coil, 10 A AC-12, 3 kW AC-2 at 400 V, screw terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-1AH01-ZW95 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-1AH01-ZW95 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-1AH01-ZW95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz48 V
3RT1015-1AH01-ZW95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-1AH01-ZW95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-1AH01-ZW95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1015-1AH01-ZW95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1015-1AH01-ZW95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-1AH01-ZW95 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

SIRIUS 3RT1015-1AH01-ZW95 — Power Contactor, Size S00, 24 VDC Coil

The 24 VDC coil draws its rated current at the listed operating range of 0.8 to 1.1 times the rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz — ensure the control supply stays within these bounds for reliable pick-up and drop-out. Rated for AC-12 duty at 10 A maximum, this contactor handles resistive loads up to that current. For motor duty, the AC-2 rating at 400 V is 3 kW, and the AC-4 rating at 400 V is 6.5 A — the AC-4 figure governs reversing or inching applications where the contacts break the motor at full current.

DIN Rail Integration and Wiring

Main circuit terminals accept solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max. 2x (0.75 to 4 mm²). AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12. Front and terminal protection is IP20. Dimensions: 45 mm wide, 57.5 mm high, 72 mm deep — fits standard S00 footprint. Pollution degree 3 for industrial environments.

For type 1 coordination, the required fuse is gL/gG 35 A; for type 2 coordination, it is gL/gG 20 A.

Frequently asked questions

Where can I buy 3RT1015-1AH01-ZW95 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing.

What are the key ratings of 3RT1015-1AH01-ZW95?

Key ratings include: 24 VDC coil, 10 A AC-12 maximum operating current, 3 kW AC-2 at 400 V, 6.5 A AC-4 at 400 V, and 4 kW at 690 V.

What is the depth of 3RT1015-1AH01-ZW95?

The depth is 72 mm, with a width of 45 mm and height of 57.5 mm, fitting the standard S00 contactor footprint.

What wire sizes does 3RT1015-1AH01-ZW95 accept?

Main circuit terminals accept solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max. 2x (0.75 to 4 mm²). AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12.

Will 3RT1015-1AH01-ZW95 drop into a panel specified for 3RT1016-1AG61?

Both are size S00 contactors with the same DIN rail mounting and similar footprint. The 3RT1016-1AG61 has a different coil voltage and ratings; verify the coil voltage and load ratings match your application before substitution.

MPN