Siemens 3RT1015-1AR61 — Contactors

Siemens 3RT1015-1AR61 SIRIUS Power Contactor, 24 VDC Coil, 1

MPN3RT1015-1AR61

Siemens SIRIUS power contactor, size S00, 24 VDC coil, 10 A AC-12, 3 kW at 400 V AC-2, screw terminals, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-1AR61 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-1AR61 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-1AR61 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.85 ... 1.1
Rated value @ 50 Hz400 V
3RT1015-1AR61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-1AR61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-1AR61 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1015-1AR61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1015-1AR61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-1AR61 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The 24 VDC coil draws the contactor in, rated for continuous duty. At AC-12 (resistive load) it handles 10 A; at AC-2 (slip-ring motor starting) it delivers 3 kW at 400 V, and at AC-4 (plugging/inching) it carries 6.5 A at 400 V. For a 3-phase motor at 400 V 50 Hz, the rated operational power is 3 kW (AC-3 duty, though not explicitly listed, the AC-2 and AC-4 figures bracket the typical motor-switching range).

The 3RT1015-1AR61 occupies 45 mm width on the DIN rail, with a depth of 72 mm and height of 57.5 mm. The screw terminals accept solid or stranded conductors: 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or max 2x (0.75–4 mm²); AWG equivalents are 2x (20–16), 2x (18–14), and 1x 12.

For type 1 coordination (no damage to contactor after short circuit, but may need replacement), the required fuse is gL/gG 35 A. For type 2 coordination (contactor remains operational after fault), use gL/gG 20 A. These ratings apply to the main circuit; the auxiliary contact is rated for 1 A at 110 V, 0.3 A at 220 V, and 2 A at 60 V. The contactor has a typical mechanical life of 30 million operations, reflecting the S00 frame's durability in high-cycle applications.

Frequently asked questions

What is 3RT1015-1AR61's depth?

The depth is 72 mm, with a width of 45 mm and height of 57.5 mm.