Skip to main content
Siemens 3RT1015-1AV61 — Contactors

Siemens 3RT1015-1AV61 SIRIUS Power Contactor, Size S00, 3-Po

MPN3RT1015-1AV61

Siemens SIRIUS power contactor, 3RT1015-1AV61, Size S00, 3 NO main contacts, 24 VDC coil, screw terminals, IP20 finger-safe, DIN rail mount.

$239.15Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-1AV61 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-1AV61 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-1AV61 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1015-1AV61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-1AV61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-1AV61 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1015-1AV61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1015-1AV61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1015-1AV61 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It's the go-to for switching motor loads up to 4 kW at 690 V (AC-3 duty) or resistive loads up to 10 A at 24 V in control panels. The screw-type terminals on both main and auxiliary circuits accept 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded, with a max of 2x (0.75 to 4 mm²) — so it handles standard panel wiring without adapters.

Ratings that matter for the BOM line

The 3RT1015-1AV61's AC-3 motor-switching capability is what most buyers need to confirm: 3 kW at 400 V, 3.5 kW at 500 V, and 4 kW at 690 V — so it covers standard 400 V three-phase motors up to about 4 kW (roughly 5.5 HP). The coil holds at 24 VDC nominal, and the contactor is rated for 30 million mechanical operations, so it'll outlast the machine in most cycling applications.

The Size S00 footprint is 45 mm wide by 57.5 mm tall by 72 mm deep — it tucks into tight DIN-rail rows. The screw terminals are clearly marked and accept AWG 20–14 for main and auxiliary circuits (2x conductors per terminal). For Type 1 coordination, use a 35 A gL/gG fuse upstream; for Type 2, a 20 A gL/gG fuse limits fault energy to protect the contactor. That's a real time-saver during panel design — no guessing the fuse size.

MPN