Siemens 3RT1015-1MB41-0KT0 — Contactors

Siemens 3RT1015-1MB41-0KT0 SIRIUS Power Contactor, 24 VDC Co

MPN3RT1015-1MB41-0KT0

Siemens SIRIUS 3RT1015-1MB41-0KT0, size S00 power contactor, 24 VDC coil, screw terminals, 3 kW at 400 V AC-3, 45 mm width, snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-1MB41-0KT0 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-1MB41-0KT0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 kW
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-1MB41-0KT0 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1015-1MB41-0KT0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-1MB41-0KT0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-1MB41-0KT0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1015-1MB41-0KT0 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RT1015-1MB41-0KT0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1015-1MB41-0KT0 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

What this contactor is and what it does

The Siemens SIRIUS 3RT1015-1MB41-0KT0 is a size S00 power contactor designed for switching 3-phase motor loads up to 3 kW at 400 V in AC-3 duty, or 4 kW at 690 V. The 24 VDC coil draws 1.4 W holding power, so it stays cool in a sealed panel and places minimal load on a 24 VDC supply. Screw-type terminals on both main and auxiliary circuits accept up to 4 mm² stranded or 12 AWG solid, which covers most motor branch wiring up to the contactor's rating.

Mounting and panel fit

Mounts via screw or snap-on onto 35 mm standard mounting rail per DIN EN 50022. The 45 mm width and 57.5 mm height match the S00 footprint, and side-by-side mounting is supported with 6 mm clearance at the side. IP20 on the front and terminals means it's protected against finger contact but needs enclosure for washdown or dust.

Coordination and protection

For Type 2 coordination (no damage to the contactor on a short circuit), use a 20 A gL/gG fuse upstream. For Type 1 coordination (contactor may need replacement after fault), a 35 A gL/gG fuse is sufficient. The pollution degree 3 rating means it's suitable for industrial environments with conductive dust or moisture — typical for control panels in factories.

Frequently asked questions

What is the closest functional alternative if I need a different coil voltage?

The 3RT1015-1BB42 uses an AC coil but shares the same S00 frame, screw terminals, and 3 kW at 400 V AC-3 rating. It drops into the same panel footprint without rewiring the power circuit — only the coil supply changes.

What are the key ratings for this contactor?

Rated for 3 kW at 400 V AC-3, 4 kW at 690 V AC-3, and 6.5 A at 400 V AC-4. The coil is 24 VDC, 1.4 W holding power. Type 2 coordination requires a 20 A gL/gG fuse.

Will this contactor fit a panel designed for the 3RT1015-1BB42?

Yes — same S00 size, same 45 mm width, same screw and snap-on DIN rail mount. The power terminals accept the same wire ranges. The only difference is the coil voltage (24 VDC vs AC), so the control wiring needs to match the coil supply.

MPN
3RT1015-1MB41-0KT0