Skip to main content
Siemens 3RT1015-2AF04-ZX95 — Contactors

Siemens 3RT1015-2AF04-ZX95 SIRIUS Power Contactor, S00, 10A

MPN3RT1015-2AF04-ZX95

Siemens SIRIUS power contactor, size S00, order code 3RT1015-2AF04-ZX95, 45 mm width, spring-loaded terminals, 10 A AC-12 rated operational current.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-2AF04-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-2AF04-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-2AF04-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1015-2AF04-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-2AF04-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-2AF04-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1015-2AF04-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1015-2AF04-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-2AF04-ZX95 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth114 mm

Product details

The Siemens 3RT1015-2AF04-ZX95 is a SIRIUS-brand power contactor in the S00 frame size, rated for switching motor loads up to 3 kW at 400 V in AC-2 duty and 6.5 A in AC-4 duty. It snaps onto a 35 mm DIN rail per EN 50022 and uses spring-loaded terminals on the main circuit, accepting 2x (0.25 to 2.5 mm²) solid or stranded wire. The 45 mm width and 114 mm depth make it a standard panel fit for motor control centers and distribution boards.

The 10 A AC-12 rating governs resistive load switching — that's the maximum continuous current through the main contacts in a non-inductive circuit. For motor duty, the AC-2 rating of 3 kW at 400 V applies to slip-ring motors where the contactor makes and breaks at reduced current; the AC-4 rating of 6.5 A at 400 V covers plugging and inching of squirrel-cage motors, which stresses the contacts harder. The auxiliary contact block handles 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — these are the switching capacities for control circuits, not continuous carry.

Coordination and wiring

The front face carries IP20 finger protection; the terminals themselves are also rated IP20.

Frequently asked questions

What is the closest functional alternative to this contactor?

The 3RT1016-2AP02 is a higher-rated sibling in the same SIRIUS S00 frame — it handles 12 A AC-12 versus 10 A on this part, and uses screw terminals instead of spring-loaded. Both share the same 45 mm width and DIN-rail mounting, so a panel designed for one can accept the other with terminal adaptation. The deciding factor is whether your wire terminations are cage-clamp (this part) or screw-clamp (the 3RT1016).

What wire sizes does the spring-loaded terminal accept?

The main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or stranded conductors, or 2x AWG 24 to 14. The spring cage holds the wire without needing a ferrule, though ferruled stranded wire is also accepted within the same cross-section range.

What fuse coordination is required for this contactor?

For Type 2 coordination (contactor survives a short circuit), use a gL/gG fuse rated 20 A. For Type 1 coordination (contactor may be damaged and need replacement), a 35 A gL/gG fuse is permitted. These values apply to the main circuit protection.

Does this part drop into a panel designed for the 3RT1016-2AP02?

Yes, the 45 mm width, 60 mm height, and 114 mm depth are identical between the two, and both mount on the same 35 mm DIN rail. The only difference is the terminal type — spring-loaded on this part versus screw on the 3RT1016 — so no panel rework is needed, just a terminal adapter if your existing wiring uses screw-clamp ferrules.

MPN