Siemens 3RT1015-2AM21 — Contactors

Siemens 3RT1015-2AM21 SIRIUS S00 Power Contactor, 24 VDC Coi

MPN3RT1015-2AM21

Siemens SIRIUS S00 power contactor, 3RT1015-2AM21, 24 VDC coil, spring-loaded terminals, AC-3 rated 5.5 kW at 400 V, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-2AM21 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-2AM21 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-2AM21 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz208 V
3RT1015-2AM21 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-2AM21 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-2AM21 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1015-2AM21 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1015-2AM21 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-2AM21 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

The 3RT1015-2AM21: Main circuit connections use spring-loaded terminals, accepting 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG). This is a tool-less push-in termination — good for panel build speed, but verify the ferrule spec if using stranded on the customer's AML. The auxiliary contact block is a single instantaneous contact (NO or NC, not specified here).

Switching capacity and coordination

For motor switching, the AC-3 rating at 400 V is 5.5 kW (the standard induction-motor duty). The AC-4 rating (plugging/reversing/inching) at 400 V is 6.5 A — significantly lower, as expected for high-stress switching. Auxiliary contact ratings are given for DC switching: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V. For AC auxiliary loads at 230 V, it handles 6 A; at 400 V, 3 A. For fuse coordination, Type 2 coordination requires a gL/gG 20 A fuse; Type 1 coordination allows a 35 A gL/gG fuse.

Pollution degree 3 (conductive pollution, typical for industrial control panels).

Frequently asked questions

What are the key dimensions for panel layout?

Width is 45 mm, height 60 mm, depth 73 mm. It mounts on 35 mm DIN rail per EN 50022, with a 6 mm side gap recommended for heat dissipation when mounting multiple units side-by-side.

What wire sizes does the spring-loaded terminal accept?

The main circuit spring terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG). Use ferruled stranded for reliable push-in termination.

MPN
3RT1015-2AM21