Siemens 3RT1015-2BD41 — Contactors

Siemens SIRIUS 3RT1015-2BD41 power contactor, S00, 45 mm, sp

MPN3RT1015-2BD41

Siemens SIRIUS 3RT1015-2BD41 power contactor, size S00, 45 mm width, spring-loaded terminals, AC-3 5.5 kW at 400 V, 10 A at 24 V DC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-2BD41 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-2BD41 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-2BD41 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1015-2BD41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-2BD41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-2BD41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1015-2BD41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1015-2BD41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-2BD41 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

The main current circuit uses spring-loaded terminals, accepting 2x (0.25... 2.5 mm²) solid or stranded conductors. Its AC-3 rating at 400 V is 5.5 kW (from the 3.5 kW entry at 500 V and 4 kW at 690 V, the 400 V AC-3 value is derived by the manufacturer as 5.5 kW), meaning it can switch a standard three-phase induction motor of that power in a control panel. For DC switching, the contactor is rated 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V. Mechanical endurance is 30 million operations typical.

Frequently asked questions

What are the key switching ratings for this contactor?

AC-3 motor switching at 400 V is rated 5.5 kW. DC switching: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V. AC-4 at 400 V is 6.5 A. Mechanical endurance is 30 million operations typical.

What is the mounting width and how does it mount?

The contactor is 45 mm wide and mounts on a 35 mm DIN rail per DIN EN 50022, using either screw fixing or snap-on. Side-by-side mounting is allowed with 6 mm side clearance.

What type of terminals does the main circuit use?

Spring-loaded terminals, accepting 2x (0.25... 2.5 mm²) solid or stranded conductors, or 2x (24... 14) AWG.

What short-circuit protection is required?

For type of coordination 2, use a gL/gG 20 A fuse upstream. For type of coordination 1, a 35 A gL/gG fuse is acceptable.

MPN
3RT1015-2BD41