Skip to main content
Siemens 3RT1015-2BW41 — Contactors

Siemens 3RT1015-2BW41 SIRIUS Power Contactor, S00, 24 VDC Co

MPN3RT1015-2BW41

Siemens SIRIUS power contactor, size S00, 3RT1015-2BW41, 24 VDC coil, spring-loaded terminals, IP20, 45 mm width, 73 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-2BW41 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-2BW41 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-2BW41 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1015-2BW41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-2BW41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-2BW41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1015-2BW41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1015-2BW41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-2BW41 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Siemens 3RT1015-2BW41 SIRIUS Power Contactor — S00 Frame, 24 VDC Coil, Spring-Loaded Terminals

Rated operational currents span 10 A at 24 V up to 0.3 A at 220 V in the DC switching curve, and motor power ratings reach 3 kW at 400 V AC-2 duty or 4 kW at 690 V. The 24 VDC coil draws 3.3 W holding power, with a pickup threshold of 0.85 x rated voltage and a dropout below the 1.1 x full-scale ceiling — a standard DC solenoid curve that panel builders can budget without surprises.

AC-4 at 400 V is rated 6.5 A — that covers plugging or inching duty on squirrel-cage motors, where the contactor sees the locked-rotor current each cycle. For resistive loads (AC-12), the maximum operating current is 10 A. Type 1 coordination allows up to 35 A. Pollution degree 3 (conductive pollution) means the contactor is suited for industrial environments where temporary condensation or light dust is expected — no additional conformal coating needed for standard panel conditions. The IP20 rating on the front and terminals means the contactor is touch-safe for panel interiors but not washdown-rated; keep it behind an enclosure door in wet areas.

Panel Fit and Wiring — S00 Footprint, Spring-Cage Terminals

The spring-loaded terminal accepts 2x (0.25 to 2.5 mm²) or 2x (24 to 14 AWG). Side-by-side mounting is permitted, which simplifies multi-contactor assemblies for star-delta or reversing starters.

Sourcing and Lifecycle — Active Part, Quoted to Order

Frequently asked questions

Will 3RT1015-2BW41 drop into a panel that was specified around 3RT1015-1BB42 without rewiring?

The 3RT1015-2BW41 uses spring-loaded terminals, while the 3RT1015-1BB42 uses screw terminals. Both share the same S00 frame size, 45 mm width, and DIN-rail mounting pattern, so the mechanical fit is identical. The wiring difference is the terminal type — spring-cage vs. screw clamp — so the panel layout and wire routing are compatible, but the termination method changes.

MPN
3RT1015-2BW41