Siemens 3RT1015-2HB41-ZX95 SIRIUS Power Contactor, S00, 24 V

MPN3RT1015-2HB41-ZX95

Siemens SIRIUS, power contactor, 3RT1015-2HB41-ZX95, Size S00, 24 V DC coil, spring-loaded terminals for main circuit, AC-2 rated 3 kW at 400 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-2HB41-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-2HB41-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-2HB41-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1015-2HB41-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-2HB41-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-2HB41-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1015-2HB41-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RT1015-2HB41-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-2HB41-ZX95 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

It carries a 24 V DC coil with a holding power of 2.3 W, and its main circuit connects via spring-loaded terminals — no screwdriver needed for the power wires, which speeds up panel wiring and reduces loose-connection callbacks. For AC-4 inching and plugging duty it manages 6.5 A at 400 V. The AC-12 resistive load maximum is 10 A.

The IP20 front and terminal protection means it is finger-safe inside an enclosure but not rated for washdown. Spring-loaded terminals on the main circuit accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). The auxiliary contact block is a separate add-on — the base unit carries one instantaneous contact.

For Type 2 coordination (no-weld after fault), use a gL/gG fuse rated 20 A. For Type 1 coordination (welding allowed but no fire risk), the fuse can go up to 35 A. The contactor is rated for use at altitudes up to 2 000 m and ambient temperatures from -25 °C to +60 °C during operation, with pollution degree 3.

Frequently asked questions

How do I get current pricing and availability for 3RT1015-2HB41-ZX95?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and stock position are confirmed at quote time.

What is the closest functional second-source to 3RT1015-2HB41-ZX95?

The closest sibling is the 3RT1015-1BB42, which shares the same S00 frame and 24 V DC coil but uses screw terminals instead of spring-loaded terminals on the main circuit. If your panel is wired with ferrules and screw clamps, the 1BB42 drops in without rewiring the control side — just check the main circuit termination preference.

Will 3RT1015-2HB41-ZX95 drop into a panel specified around 3RT1015-1BB42 without rewiring?

Yes, the physical footprint (45 x 60 x 73 mm) and DIN-rail mounting are identical. The coil voltage is the same 24 V DC. The only difference is the main circuit termination: spring-loaded on this unit versus screw clamps on the 1BB42. If your existing wiring uses screw terminals, you will need to adapt or re-terminate the power wires for the spring cage.

MPN
3RT1015-2HB41-ZX95