Siemens 3RT1015-2WB42 — Contactors

Siemens 3RT1015-2WB42 SIRIUS Power Contactor, S00, 24 VDC, 4

MPN3RT1015-2WB42

Siemens SIRIUS power contactor, size S00, 24 VDC coil, spring-loaded terminals, 4 kW at 690 V AC-3, 3RT1015-2WB42.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1015-2WB42 — Identification
ParameterValue
Contactor frame sizeS00
3RT1015-2WB42 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V3.5 kW
Rated value @ 690 V4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1015-2WB42 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1015-2WB42 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1015-2WB42 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1015-2WB42 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1015-2WB42 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RT1015-2WB42 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1015-2WB42 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

The main circuit uses spring-loaded terminals, accepting 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). The coil is 24 VDC, with a closing and holding power of 1.4 W DC. A built-in varistor provides surge suppression across the coil. Rated operational power is 3.5 kW at 500 V and 4 kW at 690 V, with a maximum operating current of 10 A for AC-12 duty. For motor switching, the AC-3 rating is the key figure: 6 A at 230 V, 3 A at 400 V.

The S00 frame size (45 mm wide, 60 mm high, 73 mm deep) fits standard 45 mm-wide contactor slots on a DIN rail. Pollution degree 3 (conductive or dry non-conductive pollution) is the standard for industrial control environments. Type 1 (contactor may need replacement) allows a 35 A gL/gG fuse. Pick-up voltage is 0.85 x rated and drop-out is 1.85 x rated.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 45 mm, height is 60 mm, depth is 73 mm. Side-by-side mounting requires 6 mm spacing to adjacent devices.

What wire sizes does the spring-loaded terminal accept?

The main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG).

MPN
3RT1015-2WB42