Skip to main content
Siemens 3RT1016-1AB01-ZW96 — Contactors

Siemens 3RT1016-1AB01-ZW96 SIRIUS Power Contactor, Size S00,

MPN3RT1016-1AB01-ZW96

Siemens SIRIUS 3RT1016-1AB01-ZW96 power contactor, Size S00, 24 V AC 50/60 Hz coil, 10 A rated operational current, screw terminals, snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1AB01-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1AB01-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1AB01-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1016-1AB01-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1AB01-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1AB01-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1016-1AB01-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1AB01-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-1AB01-ZW96 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens 3RT1016-1AB01-ZW96 is a SIRIUS power contactor in the compact Size S00 frame — 45 mm wide, 57.5 mm tall, 72 mm deep — designed for switching motor loads and resistive loads in control panels. The 24 V AC coil operates at 50/60 Hz with a voltage tolerance of 0.8...1.1 x Us at 50 Hz and 0.85...1.1 x Us at 60 Hz. Rated operational current is 10 A at 24 V, with motor-switching capability of 4.5 kW at 500 V and 5.5 kW at 690 V. For AC-2 duty at 400 V it handles 4 kW; AC-4 at 400 V is rated at 8.5 A — the AC-4 figure is the one to watch for reversing or inching applications where the contactor makes and breaks stalled-rotor current.

Side-by-side mounting is allowed with a 6 mm gap at the side, which keeps heat rise under control when multiple contactors are ganged on the rail. The front face carries IP20 finger-safe protection; the terminals themselves are also rated IP20, so no additional shrouding is needed inside a closed panel. Wire range for the main contacts accepts 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), or max 2x (0.75...4 mm²) solid/stranded, with AWG equivalents of 2x (20...16), 2x (18...14), and 1x 12. That covers most panel wiring up to 4 mm² without needing ferrule adapters.

Environmental and protection ratings

Above that, air density drops and clearance/creepage distances need re-evaluation — not a concern for most low-voltage panels.

Frequently asked questions

Does this contactor drop into a panel designed for the 3RT1016-2AP02?

The 3RT1016-1AB01-ZW96 shares the same Size S00 footprint (45 x 57.5 x 72 mm) and DIN rail mounting as the 3RT1016-2AP02. The main difference is the coil voltage — this one is 24 V AC, while the 2AP02 variant uses a different coil. If the panel wiring and control transformer are already sized for 24 V AC, it's a mechanical drop-in. Verify the coil supply before swapping.

What wire sizes does the screw terminal accept?

The main circuit terminals accept 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), or max 2x (0.75...4 mm²) solid/stranded copper. AWG equivalents are 2x (20...16), 2x (18...14), and 1x 12. No ferrule required for stranded within those ranges.

MPN
3RT1016-1AB01-ZW96