Skip to main content
Siemens 3RT1016-1AF05-ZX95 — Contactors

Siemens 3RT1016-1AF05-ZX95 SIRIUS Power Contactor, S00, 24 V

MPN3RT1016-1AF05-ZX95

Siemens SIRIUS power contactor, size S00, 3RT1016-1AF05-ZX95, 24 V DC coil, 10 A rated, screw terminals, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1AF05-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1AF05-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1AF05-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1016-1AF05-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1AF05-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1AF05-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1016-1AF05-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1AF05-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-1AF05-ZX95 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth114 mm

Product details

The Siemens SIRIUS 3RT1016-1AF05-ZX95 is a size S00 power contactor rated for 10 A at 24 V DC, with screw-type terminals and snap-on mounting onto 35 mm DIN rail per EN 50022. It carries three instantaneous main contacts and is designed for switching motor loads in control panels — the S00 frame keeps the footprint to 45 mm wide by 57.5 mm tall by 114 mm deep, which fits standard panel layouts without crowding adjacent devices.

The 10 A rating at 24 V DC is the continuous current the main contacts carry in DC control circuits — sized for switching solenoids, small DC motors, or resistive loads in a 24 VDC panel. For AC motor duty, the contactor is rated 4.5 kW at 500 V (AC-3) and 5.5 kW at 690 V, meaning it handles standard three-phase induction motors up to those power levels.

Wire sizes for main contacts accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid/stranded, plus AWG equivalents 2x (20–16), 2x (18–14), and 1x 12. For type 2 coordination, use a gL/gG fuse rated 20 A; for type 1 coordination, 35 A.

Frequently asked questions

Where can I buy 3RT1016-1AF05-ZX95 and how do I get a price?

This contactor is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer.

What is the depth of 3RT1016-1AF05-ZX95?

The depth is 114 mm, which fits standard panel depths without crowding.

What wire sizes does the main terminal accept?

The screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded, plus AWG 2x (20–16), 2x (18–14), and 1x 12.

Will 3RT1016-1AF05-ZX95 drop into a panel specified for 3RT1016-1AR11?

Both are size S00 contactors on the same 45 mm wide footprint with screw terminals and snap-on DIN rail mounting, so the mechanical fit and wiring space are identical. The difference is the coil voltage — 3RT1016-1AF05-ZX95 uses 24 V DC, while 3RT1016-1AR11 uses a different coil voltage. Check the coil rating on your BOM before swapping.

MPN
3RT1016-1AF05-ZX95