Siemens 3RT1016-1AN11 — Contactors

Siemens 3RT1016-1AN11 SIRIUS Power Contactor, 3 NO, 45 mm, 2

MPN3RT1016-1AN11

Siemens SIRIUS 3RT1016-1AN11 power contactor, size S00, 3 NO main contacts, 220 V 60 Hz coil, screw terminals, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1AN11 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1AN11 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1AN11 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1016-1AN11 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1AN11 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1AN11 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1016-1AN11 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1AN11 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1016-1AN11 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It carries three normally-open main contacts and is rated for a 220 V 60 Hz coil supply.

For motor switching duty, the 3RT1016-1AN11 is rated at 4 kW at AC-2 at 400 V, meaning it handles wound-rotor motor starting and reversing loads up to that power. At AC-4 at 400 V, the rated operational current is 8.5 A, which covers plugging and inching duty for squirrel-cage motors within that current envelope. The coil draws its rated supply at 220 V 60 Hz, with an operating range of 0.8 to 1.1 times the rated value — so the coil holds in from 176 V to 242 V at 60 Hz. Short-circuit coordination is specified: type 2 coordination requires a gL/gG fuse rated 20 A, while type 1 coordination requires 35 A. This determines the upstream fuse sizing for the motor branch circuit.

Its width is 45 mm, height 57.5 mm, and depth 72 mm — a compact S00 footprint that fits standard DIN-rail enclosures. Side-by-side mounting is permitted, which means multiple contactors can be ganged on the rail without derating for heat dissipation — useful for compact motor starter assemblies. The enclosure offers IP20 protection on the front and at the terminals, meaning finger-safe but not protected against water ingress — suitable for dry indoor panel environments only.

Terminal details and wiring

Both main current circuit and auxiliary/control circuit terminals are screw-type. The main contacts accept solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or a maximum of 2x (0.75 to 4 mm²). AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12. Auxiliary contact terminals accept the same conductor cross-sections as the main contacts.

Operating environment

The product carries a RoHS compliance date of 01.07.2006, indicating it meets the EU RoHS directive for restricted substances. The IEC 81346-2 reference code is Q, which designates switching devices in the standard designation system.

Frequently asked questions

What are the main contact ratings for motor duty?

At AC-2 at 400 V, the contactor is rated for 4 kW. At AC-4 at 400 V, the rated operational current is 8.5 A.

What coil voltage does this contactor use?

The coil is rated for 220 V at 60 Hz, with an operating range of 0.8 to 1.1 times the rated value.

What is the physical size and mounting method?

Width is 45 mm, height 57.5 mm, depth 72 mm. It mounts via screw fixing or snap-on onto a 35 mm DIN rail per EN 50022.

What conductor sizes does the screw terminal accept?

Main and auxiliary terminals accept solid or stranded: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²). AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12.

What compliance documentation is available?

The product meets RoHS compliance per the 01.07.2006 date. The IEC 81346-2 reference code is Q.