Siemens 3RT1016-1AP01-ZX95 — Contactors

Siemens 3RT1016-1AP01-ZX95 SIRIUS Power Contactor, Size S00,

MPN3RT1016-1AP01-ZX95

Siemens SIRIUS power contactor, size S00, 3RT1016-1AP01-ZX95, 45 mm width, screw-type terminals, 5.5 kW at 690 V AC-3, IP20, current lifecycle stage.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1AP01-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1AP01-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1AP01-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1016-1AP01-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1AP01-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1AP01-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1016-1AP01-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1AP01-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-1AP01-ZX95 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

Its 45 mm width fits standard DIN-rail layouts, and the screw-type terminals on the main circuit accept conductors from 2x (0.5... 1.5 mm²) up to 2x (0.75... 4 mm²) solid or stranded, with AWG equivalents of 2x (20... 16) through 1x 12. Rated for AC-3 duty at 4.5 kW at 500 V and 5.5 kW at 690 V, this contactor handles three-phase motor switching up to those power levels.

The 30 million typical mechanical cycles means this contactor is built for high-duty-cycle applications like conveyor lines or pump stations where the contactor cycles frequently. The IP20 rating on the front and terminals means it needs a panel enclosure for dust and touch protection — standard for a DIN-rail component inside a cabinet. Type 2 coordination requires a 20 A gL/gG fuse — this limits fault energy so the contactor remains usable after a short circuit. Type 1 coordination uses a 35 A gL/gG fuse but the contactor may need replacement after a fault. The choice depends on your panel's selectivity and maintenance strategy.

The S00 frame size (45 × 57.5 × 72 mm) is the smallest in the SIRIUS contactor family, saving panel space while still handling up to 5.5 kW at 690 V.

The -ZX95 suffix indicates a special version — verify the specific coil voltage and auxiliary contact configuration against your BOM before committing. The base ratings (5.5 kW at 690 V AC-3, 30 million cycles) are the same as the standard 3RT1016 family.

Frequently asked questions

What are the key power ratings for this contactor?

AC-3 motor rating: 4.5 kW at 500 V and 5.5 kW at 690 V. AC-4 reversing duty: 8.5 A at 400 V. AC-2 duty: 4 kW at 400 V.

What wire sizes does the screw terminal accept?

Main circuit terminals accept 2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²), max. 2x (0.75... 4 mm²) solid or stranded, and AWG 2x (20... 16), 2x (18... 14), 1x 12.

Can this contactor be mounted side-by-side with others?

Yes, side-by-side mounting is allowed with 6 mm spacing at the side. No derating required for adjacent units.

What fuse coordination is recommended?

Type 2 coordination: 20 A gL/gG fuse. Type 1 coordination: 35 A gL/gG fuse. Type 2 keeps the contactor usable after a fault; Type 1 may require replacement.