Siemens 3RT1016-1AP02-ZW98 — Contactors

Siemens 3RT1016-1AP02-ZW98 SIRIUS Contactor, S00, 45 mm

MPN3RT1016-1AP02-ZW98

Siemens SIRIUS power contactor, size S00, 3RT1016-1AP02-ZW98, 45 mm width, screw terminals, 4 kW at AC-2 400 V, 8.5 A at AC-4 400 V, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1AP02-ZW98 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1AP02-ZW98 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1AP02-ZW98 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1016-1AP02-ZW98 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1AP02-ZW98 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1AP02-ZW98 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1016-1AP02-ZW98 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1AP02-ZW98 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-1AP02-ZW98 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

At 45 mm wide, 57.5 mm tall, and 72 mm deep, it occupies a single 45 mm module on the rail — a compact footprint that leaves room for auxiliary contact blocks or overload relays alongside it on the same DIN rail.

Rated at 4 kW at AC-2 duty on 400 V, this contactor handles slip-ring motor loads — starting and running — up to that power. For AC-4 duty (plugging, inching, reversing) at 400 V, it carries 8.5 A, which is the rating that governs frequent jogging or reversing applications. The AC-12 maximum operating current is 10 A, covering resistive and solid-state loads in control circuits. The contactor is rated for a 50 Hz supply at 230 V and a 60 Hz supply at 230 V, with the coil operating range spanning 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz. That means it holds in across a sag down to about 184 V on a 230 V nominal 50 Hz line. Type 1 coordination allows a 35 A gL/gG fuse. The difference matters for panel builders: Type 2 leaves the contactor usable after a fault; Type 1 may require replacement.

Terminals and wiring

Main current circuit terminals are screw-type, accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12. The IP20 rating on the front and terminals means finger-safe for panel installation, but not protected against moisture — keep it inside a sealed enclosure.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 45 mm, height 57.5 mm, depth 72 mm. It mounts on a 35 mm DIN rail per EN 50022, occupying one 45 mm module.

What wire sizes does the screw terminal accept?

Main terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded. AWG equivalents: 2x (20 to 16), 2x (18 to 14), or 1x 12.

What is the AC-4 rating and why does it matter?

AC-4 at 400 V is rated 8.5 A. This duty covers plugging, inching, and reversing — frequent switching under load. If your application jogs or reverses a motor, use this rating, not the AC-2 or AC-3 value.

What short-circuit protection is required?

For Type 2 coordination (contactor remains usable after a fault), use a 20 A gL/gG fuse. For Type 1 coordination (contactor may need replacement), a 35 A gL/gG fuse is allowed.

MPN
3RT1016-1AP02-ZW98