Skip to main content
Siemens 3RT1016-1AQ05 — Contactors

Siemens 3RT1016-1AQ05 SIRIUS Power Contactor, S00, 24 VDC 10

MPN3RT1016-1AQ05

Siemens SIRIUS 3RT1016-1AQ05 power contactor, size S00, 3-pole, 24 VDC coil, screw-type terminals, 45 mm width, snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1AQ05 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1AQ05 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1AQ05 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz380 V
3RT1016-1AQ05 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1AQ05 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1AQ05 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1016-1AQ05 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1AQ05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-1AQ05 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth114 mm

Product details

It carries a 24 VDC coil and is rated for a 10 A operational current at 24 V (AC-12), with an AC-4 rating of 8.5 A at 400 V for reversing or inching duty.

The 10 A rating at 24 V (AC-12) covers resistive and transformer loads at that voltage. The AC-2 rating of 4 kW at 400 V applies to slip-ring motor starting. The mechanical life of 30,000,000 cycles tells you the contactor is built for high-cycle applications like conveyor or packaging lines.

The IP20 protection on the front and terminals means it's finger-safe inside an enclosure but not washdown-rated.

Screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded conductors. These are the values to specify when designing the branch circuit protection.

Frequently asked questions

What is the closest functional alternative to 3RT1016-1AQ05?

The 3RT1016-2AP02 is a peer in the same S00 frame size but uses a 24 VAC/DC coil with spring-cage terminals instead of screw-type. If your panel is wired for screw terminals, the 3RT1016-1AQ05 is the direct fit; swapping to the -2AP02 would require re-terminating the control wiring.

What are the key ratings for this contactor?

Rated operational current 10 A at 24 V (AC-12), AC-4 rating 8.5 A at 400 V, AC-2 rating 4 kW at 400 V. Coil is 24 VDC. Mechanical life 30,000,000 cycles.

What compliance documentation is available for this part?

The part carries CE marking for the European market and is designed to IEC 60947-4-1. RoHS and REACH declarations are standard for Siemens SIRIUS products. UL/CSA listings are typical for the series but should be confirmed per the specific catalog number.

Will 3RT1016-1AQ05 drop into a panel specified for 3RT1016-2AP02?

The mounting footprint (45 mm width, DIN rail) and main circuit ratings are identical. The difference is the terminal type: screw-type on the -1AQ05 versus spring-cage on the -2AP02. If the panel wiring uses ferrules or bare wire, the screw terminals are compatible; if the existing wiring is terminated with spring-cage-specific ferrules, no change is needed.

MPN
3RT1016-1AQ05