Skip to main content
Siemens 3RT1016-1AR11 — Contactors

Siemens SIRIUS 3RT1016-1AR11 Power Contactor, S00 Frame, 4 k

MPN3RT1016-1AR11

Siemens SIRIUS 3RT1016-1AR11 power contactor, size S00, 3-pole, 4 kW AC-3 at 400 V, 24 VDC coil, screw terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1AR11 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1AR11 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V4 kW
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1AR11 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1016-1AR11 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1AR11 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1AR11 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1016-1AR11 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1AR11 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1016-1AR11 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens SIRIUS 3RT1016-1AR11 is a size S00 power contactor rated for 4 kW at 400 V in AC-3 duty, meaning it switches three-phase squirrel-cage motors up to that load. The 24 VDC coil is standard for PLC-driven panels. Three normally-open main contacts handle the power circuit; there are no auxiliary contacts built into this base unit.

Short-circuit coordination is specified: Type 2 coordination requires a 20 A gL/gG fuse, while Type 1 coordination allows a 35 A gL/gG fuse. This matters for selectivity studies and panel SCCR calculations — the fuse size directly affects the let-through energy the contactor must survive. The screw-type terminals accept 2x (0.5 to 1.5 mm²) solid, 2x (0.75 to 2.5 mm²) solid, or up to 2x (0.75 to 4 mm²) solid — covering the common control and power wiring sizes for a 4 kW motor circuit. AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12. Front IP20 protection means the contactor is safe from finger contact when mounted in an enclosure — standard for control panels.

Frequently asked questions

What is the closest functional alternative if 3RT1016-1AR11 is unavailable?

The 3RT1016-2AP02 is a sibling in the same S00 frame size with the same 4 kW AC-3 rating, but uses spring-cage terminals instead of screw terminals. The 3RT1016-1AN22 has a different coil voltage (230 VAC 50 Hz / 240 VAC 60 Hz). Verify coil voltage and terminal preference before substituting.

What is the depth of this contactor?

The depth is 72 mm from the mounting surface to the front of the device.

What wire sizes does the screw terminal accept?

Solid wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). AWG equivalents: 2x (20 to 16), 2x (18 to 14), 1x 12.

Will 3RT1016-1AR11 drop into a panel designed for 3RT1016-2AP02?

Yes, the physical footprint is identical — same S00 frame size, same 45 mm width, same DIN rail mounting. The only difference is the terminal type: screw terminals on the -1AR11 versus spring-cage terminals on the -2AP02. No rewiring of the mounting or bus bars is needed, but the wire termination method differs.

MPN
3RT1016-1AR11