Skip to main content
Siemens 3RT1016-1AU05-ZX95 — Contactors

Siemens 3RT1016-1AU05-ZX95 SIRIUS Power Contactor, S00, 24 V

MPN3RT1016-1AU05-ZX95

Siemens SIRIUS power contactor, size S00, 24 VDC coil, 5.5 kW at 690 V, AC-4 8.5 A, screw terminals, 45 x 57.5 x 114 mm, DIN rail snap-on.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1AU05-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1AU05-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1AU05-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz240 V
3RT1016-1AU05-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1AU05-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1AU05-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1016-1AU05-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1AU05-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-1AU05-ZX95 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth114 mm

Product details

The 24 VDC coil pulls in at the rated 10 A and holds reliably across the -25 to +60 °C operating range. For a 3-phase motor at 690 V it handles 5.5 kW; in AC-4 duty (plugging/inching) it's rated 8.5 A at 400 V.

The 45 mm width and 57.5 mm height leave room for a 4-pole auxiliary block alongside; side-by-side mounting is allowed with a 6 mm gap to the side. Depth of 114 mm means it clears most 200 mm enclosures, but check gland-plate clearance if the panel is shallow.

Main circuit terminals accept 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or max 2x (0.75–4 mm²) solid/stranded. For type 1 coordination use a 35 A gL/gG fuse; type 2 calls for 20 A. The IP20 finger-safe front and terminal shroud keep live parts covered in a standard panel.

Frequently asked questions

What is the depth of 3RT1016-1AU05-ZX95?

The depth is 114 mm, which fits most standard 200 mm deep enclosures.

What wire sizes does the main terminal accept?

The screw terminals accept 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or max 2x (0.75–4 mm²) solid or stranded conductors.

Where can I buy 3RT1016-1AU05-ZX95 and get current pricing?