Skip to main content
Siemens 3RT1016-1BB41-ZX95 — Contactors

Siemens 3RT1016-1BB41-ZX95 SIRIUS Power Contactor, 24 VDC Co

MPN3RT1016-1BB41-ZX95

Siemens SIRIUS power contactor, 3RT1016-1BB41-ZX95, size S00, 24 VDC coil, 4 kW at 400 V AC-3, screw terminals, IP20 front, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-1BB41-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1BB41-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V4 kW
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1BB41-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1016-1BB41-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1BB41-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1BB41-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1016-1BB41-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-1BB41-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1016-1BB41-ZX95 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The 45 mm width and 57.5 mm height fit the standard S00 footprint; depth is 72 mm, which matters when the panel depth is tight against a backplate or door. Side-by-side mounting is permitted, with 6 mm spacing at the side — no forced air gap, but the 20 A gL/gG fuse (type 2 coordination) or 35 A (type 1) sets the short-circuit protection upstream. Screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded — covers the common panel wire sizes without needing ferrules for the smaller gauges.

Frequently asked questions

What is the coil voltage and power draw for 3RT1016-1BB41-ZX95?

The coil is rated 24 V DC, drawing 3.3 W for both closing and holding power.

What motor power can this contactor switch at 400 V?

Rated 4 kW at 400 V AC-3 duty for standard motor starting, and 8.5 A at 400 V AC-4 for reversing or plugging applications.

What are the mounting dimensions of 3RT1016-1BB41-ZX95?

Width 45 mm, height 57.5 mm, depth 72 mm. Mounts on 35 mm DIN rail per EN 50022 with snap-on fastening.

What wire sizes does the screw terminal accept?

Accepts 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded conductors.

Where can I buy 3RT1016-1BB41-ZX95?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RT1016-1BB41-ZX95