Siemens 3RT1016-1HB41-ZW96 — Contactors

Siemens 3RT1016-1HB41-ZW96 SIRIUS Power Contactor

MPN3RT1016-1HB41-ZW96

Siemens SIRIUS power contactor, size S00, 3RT1016-1HB41-ZW96, 24 V DC coil, screw-type terminals, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT1016-1HB41-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-1HB41-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-1HB41-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1016-1HB41-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-1HB41-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-1HB41-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1016-1HB41-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RT1016-1HB41-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-1HB41-ZW96 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

SIRIUS S00 power contactor — 24 V DC coil, 10 A AC-12

Rated operating range covers -25 to +60 °C, so it handles unheated enclosure corners near a warm bus.

AC-1 / AC-2 / AC-4 — what the duty ratings mean for your load

That's the general-purpose rating for heaters, lighting banks, or transformer primaries where inrush is modest. AC-4 (plugging / inching / reversing) drops to 8.5 A at 400 V, reflecting the higher arcing stress of frequent reversals. If your application cycles a motor in reverse every few seconds, the AC-4 figure governs contact life, not the AC-1 number.

Terminal capacity and coordination

Screw-type terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) — solid or stranded. For AWG, that's 2x (20 to 16), 2x (18 to 14), or 1x 12. Type 2 coordination (no-weld) requires a gL/gG 20 A fuse upstream; Type 1 coordination allows a 35 A fuse. The IP20 finger-safe terminals are standard for enclosed panel use.

Frequently asked questions

Where can I buy Siemens 3RT1016-1HB41-ZW96?

This part is sourced to order; availability and pricing are confirmed at quote time.

MPN
3RT1016-1HB41-ZW96