Skip to main content
Siemens 3RT1016-2AD01 — Contactors

Siemens 3RT1016-2AD01 SIRIUS S00 Power Contactor, 4 kW AC-2

MPN3RT1016-2AD01

Siemens SIRIUS 3RT1016-2AD01, size S00 power contactor, 4 kW AC-2 at 400 V, 8.5 A AC-4, spring-loaded terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2AD01 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2AD01 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2AD01 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz42 V
3RT1016-2AD01 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2AD01 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2AD01 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2AD01 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2AD01 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2AD01 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

The main circuit uses spring-loaded terminals accepting 2x (0.25 to 2.5 mm²) solid or stranded wire, which speeds wiring and avoids the torque-check step of screw terminals.

The AC-2 rating of 4 kW at 400 V covers wound-rotor motor applications where starting current is moderate. The AC-4 rating of 8.5 A at 400 V handles plugging and inching duty — the tougher switching condition for contactor life. For DC switching, it's rated 10 A at 24 V and 0.3 A at 220 V, which covers small solenoid and brake loads. For type of coordination 2 (fault protection with limited damage), the required fuse is gL/gG 20 A. For type 1 coordination (immediate replacement after fault), it's gL/gG 35 A. This lets the panel designer match the upstream protection to the acceptable downtime.

The front face carries IP20 finger protection; the terminals are also IP20.

Frequently asked questions

What are the key ratings for this contactor?

AC-2 motor rating is 4 kW at 400 V. AC-4 rating is 8.5 A at 400 V. DC switching: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V. Mechanical life is 30 million operations typical.

What wire sizes does the spring terminal accept?

The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG). No special tools beyond a screwdriver for the spring release.

What is the closest functional alternative to this part?

The 3RT1016-2AP02 is a direct peer in the same S00 frame with identical mounting and terminal style. The main difference is the coil voltage — the -2AD01 uses a 24 V DC coil, while the -2AP02 uses a different coil voltage. Verify coil compatibility before substituting.

Will this drop into a panel wired for 3RT1016-2AP02?

Mechanically yes — same S00 frame, same 45 mm width, same DIN rail mounting. The spring terminals are identical. The only difference is the coil voltage; if the panel supplies 24 V DC, the -2AD01 is a direct swap without rewiring.

MPN
3RT1016-2AD01