Siemens 3RT1016-2AF02 — Contactors

Siemens 3RT1016-2AF02 SIRIUS Power Contactor, S00, 5.5 kW at

MPN3RT1016-2AF02

Siemens SIRIUS power contactor, size S00, 3RT1016-2AF02, 5.5 kW at 690 V, spring-loaded terminals, 45 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2AF02 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2AF02 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2AF02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1016-2AF02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2AF02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2AF02 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2AF02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2AF02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2AF02 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Rated for 5.5 kW at 690 V and 4.5 kW at 500 V, this contactor handles three-phase motors up to those power levels. AC-2 at 400 V is 4 kW, for slip-ring motor starting. Mechanical life is typical 30,000,000 operations. Pollution degree 3.

For type 1 coordination (contactor may need replacement after a fault), the fuse can go up to 35 A. This is the standard protection scheme for S00 contactors driving motor loads. The coil itself pulls 0.8 to 1.1 A at 50 Hz, and 0.85 to 1.1 A at 60 Hz, depending on the control voltage.

The contactor is 45 mm wide, 60 mm tall, and 73 mm deep — a compact S00 footprint that fits standard 45 mm spacing on the DIN rail. Side-by-side mounting is allowed, with a 6 mm clearance to the side for heat dissipation. The front is IP20, so finger-safe for panel wiring. Main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). Spring-loaded means strip and push — no torque spec to check.

Frequently asked questions

Will 3RT1016-2AF02 fit in a panel designed for 3RT1016-2AP02?

Yes, the physical dimensions are identical — 45 mm wide, 60 mm tall, 73 mm deep. Both mount on 35 mm DIN rail. The only difference is the terminal type: spring-loaded on the 2AF02 vs screw on the 2AP02. No rewiring of the panel layout is needed.

MPN
3RT1016-2AF02