Siemens 3RT1016-2AH02 — Contactors

Siemens 3RT1016-2AH02 SIRIUS power contactor, 45 mm, spring

MPN3RT1016-2AH02

Siemens SIRIUS 3RT1016-2AH02 power contactor, size S00, 45 mm width, spring-loaded terminals, AC-4 8.5 A at 400 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2AH02 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2AH02 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2AH02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz48 V
3RT1016-2AH02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2AH02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2AH02 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2AH02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2AH02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2AH02 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Its spring-loaded main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or stranded wire — no screwdriver torque needed, which speeds up panel wiring and eliminates loose-terminal callbacks. The 45 mm width and snap-on mounting onto 35 mm DIN rail (DIN EN 50022) mean it fits a standard 45 mm slot in any control panel.

For motor duty, the AC-4 rating at 400 V is 8.5 A — that's the current it can switch during inching or plug reversing, the hardest thermal cycle for a contactor. The AC-2 rating at 400 V is 4 kW, covering slip-ring motor starting. For resistive or general-purpose loads, AC-12 operating current is 10 A. The coil holds at 48 V, 50/60 Hz (rated values 0.8 to 1.1 at 50 Hz, 0.85 to 1.1 at 60 Hz).

Operating temperature range is -25 to +60 °C, and altitude is rated up to 2 000 m.

Frequently asked questions

What replaces the 3RT1016-2AH02 if it becomes obsolete?

No official successor has been announced. The closest functional sibling is the 3RT1016-2AP02, which shares the same S00 frame, 45 mm width, and electrical ratings but uses screw terminals instead of spring-loaded terminals.

Will the 3RT1016-2AH02 drop into a panel specified around the 3RT1016-2AP02?

Yes — same 45 mm width, same snap-on DIN rail mounting, same footprint. The only difference is the termination: spring-loaded on the 2AH02 versus screw on the 2AP02. No rewiring of the mounting or bus structure needed.

What is the depth of the 3RT1016-2AH02?

The depth is 73 mm. This is the dimension from the mounting surface to the frontmost point of the contactor body.

What wire sizes do the spring terminals accept?

The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded conductors, or 2x (24 to 14 AWG).

MPN
3RT1016-2AH02