Skip to main content
Siemens 3RT1016-2AP01-ZW97 — Contactors

Siemens 3RT1016-2AP01-ZW97 SIRIUS Power Contactor, Size S00,

MPN3RT1016-2AP01-ZW97

Siemens SIRIUS power contactor, Size S00, 24 VDC coil, 10 A rated operating current, spring-loaded terminals, screw and snap-on mounting on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2AP01-ZW97 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2AP01-ZW97 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2AP01-ZW97 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1016-2AP01-ZW97 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2AP01-ZW97 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2AP01-ZW97 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2AP01-ZW97 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2AP01-ZW97 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2AP01-ZW97 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

It mounts via screw and snap-on onto 35 mm standard mounting rail per DIN EN 50022, fitting a 45 mm wide DIN-rail footprint with 60 mm height and 73 mm depth — compact enough for dense panel layouts where every millimeter of rail space counts. The 24 VDC coil draws its rated current at the listed 10 A operating current (AC-12 maximum), with a pickup voltage range of 0.8 to 1.1 at 50 Hz and 0.85 to 1.1 at 60 Hz. Spring-loaded terminals on the main current circuit accept 2x (0.25 to 2.5 mm²) solid or stranded conductors, or 2x (24 to 14) AWG — no tools needed for termination, which speeds panel wiring and reduces torque-verification steps during commissioning.

The IP20 finger-safe protection on the front and terminals means it can be installed in a standard IP54 or higher enclosure without additional shrouding for the operator-facing side.

Switching capacity and coordination

Rated for AC-2 duty at 400 V at 4 kW and AC-4 at 400 V at 8.5 A, this contactor handles reversing or inching applications where the load is switched under full motor current.

Frequently asked questions

Where can I buy 3RT1016-2AP01-ZW97 and how do I get a price?

This part is sourced and quoted to order against an RFQ. Submit a request through the storefront; availability and current pricing are confirmed at quote time.

What is the closest functional second-source to 3RT1016-2AP01-ZW97?

The 3RT1016-2AP02 is the closest functional peer within the same SIRIUS Size S00 family. The key difference is the coil voltage: the -ZW97 suffix specifies a 24 VDC coil, while the -2AP02 carries a different coil rating. Both share the same 45 mm width, spring-loaded terminals, and mounting footprint, so a panel designed for one can accept the other without rewiring the main circuit — only the coil supply needs verification.

What is 3RT1016-2AP01-ZW97's listed depth?

The depth is 73 mm, with a width of 45 mm and height of 60 mm, fitting the standard Size S00 DIN-rail footprint.

What conductor sizes does the spring-loaded terminal accept?

The main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or stranded conductors, or 2x (24 to 14) AWG. No ferrule is required for stranded wire, though ferruled ends are acceptable within the same cross-section range.

Will 3RT1016-2AP01-ZW97 drop into a panel specified around 3RT1016-2AP02 without rewiring?

Yes, the mechanical footprint and terminal layout are identical — both are Size S00 with 45 mm width and spring-loaded terminals. The only difference is the coil voltage; verify that the 24 VDC coil supply matches the panel's control voltage before installation.

MPN
3RT1016-2AP01-ZW97