Siemens 3RT1016-2AP61 — Contactors

Siemens 3RT1016-2AP61 SIRIUS Power Contactor, S00, 5.5 kW at

MPN3RT1016-2AP61

Siemens SIRIUS 3RT1016-2AP61 power contactor, size S00, 4.5 kW at 500 V / 5.5 kW at 690 V AC-3, spring-loaded terminals, screw and snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2AP61 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2AP61 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2AP61 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.85 ... 1.1
Rated value @ 50 Hz220 V
3RT1016-2AP61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2AP61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2AP61 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2AP61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2AP61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2AP61 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Rated for AC-3 duty at 4.5 kW at 500 V and 5.5 kW at 690 V, it handles standard squirrel-cage induction motors up to those power levels. For AC-2 slip-ring motor duty, it's rated 4 kW at 400 V. The AC-4 reversing duty rating is 8.5 A at 400 V, which matters when you need frequent plugging or inching.

The main circuit uses spring-loaded terminals accepting 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x AWG 24 to 14. No screwdriver needed for the power connections — strip, push, done.

Environmental and protection

Rated pollution degree 3, meaning it's suitable for industrial atmospheres with conductive dust or condensation. IP20 on the front and terminals — finger-safe but not washdown-rated, so keep it inside the enclosure.

For type 1 coordination (contactor may need replacement after fault), use 35 A gL/gG fuses. Mechanical endurance is typical 30 million operations, so this is a fast mover for high-cycle applications like conveyors or packaging lines.

Frequently asked questions

What are the key motor ratings for this contactor?

AC-3 duty: 4.5 kW at 500 V, 5.5 kW at 690 V. AC-2 duty: 4 kW at 400 V. AC-4 reversing duty: 8.5 A at 400 V. The 24 V DC coil draws 10 A at rated voltage.

What wire sizes does the spring-loaded terminal accept?

The main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x AWG 24 to 14. No ferrule required for stranded, but recommended for fine-stranded wire.

Can I mount this contactor side-by-side with others?

Yes, side-by-side mounting is permitted with no spacing required. The 45 mm width and 73 mm depth allow zero-gap stacking on DIN rail without derating.

What fuse ratings are needed for type 2 coordination?

For type 2 coordination (no damage after short circuit), use gL/gG fuses rated 20 A. For type 1 coordination (contactor may need replacement), use 35 A gL/gG fuses.

MPN
3RT1016-2AP61