Skip to main content
Siemens 3RT1016-2AV02 — Contactors

Siemens 3RT1016-2AV02 SIRIUS Power Contactor, S00, 400 V, 10

MPN3RT1016-2AV02

Siemens SIRIUS series, 3RT1016-2AV02 power contactor, S00 frame, spring-loaded terminals, 400 V rated, 10 A AC-12, screw and snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2AV02 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2AV02 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2AV02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RT1016-2AV02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2AV02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2AV02 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2AV02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2AV02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2AV02 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Mounting and integration

The 3RT1016-2AV02: Mounts via screw or snap-on onto 35 mm DIN rail per EN 50022. The 45 mm width and 60 mm height fit a standard 6-module enclosure slot; 73 mm depth leaves clearance for front-panel wiring ducts. Side-by-side mounting is permitted without derating, so you can gang multiple contactors on a single rail for multi-motor groups. IP20 on the front and at the terminals means it's protected against finger contact but requires enclosure in a panel rated for the environment.

Coordination and protection

For Type 2 coordination (no damage after a short circuit), use a gL/gG fuse rated 20 A. For Type 1 coordination (allowable damage but safe interruption), the fuse can go up to 35 A. The degree of pollution 3 rating means the contactor is suitable for industrial environments with conductive dust or moisture — common in machine-tool and conveyor applications.

Frequently asked questions

What is the closest functional alternative to 3RT1016-2AV02?

The 3RT1016-2AP02 is a sibling in the same S00 frame and coil voltage family. The key difference is the terminal type: 2AV02 uses spring-loaded terminals, while 2AP02 uses screw terminals. The spring version saves wiring time and resists loosening under vibration; the screw version is preferred where field rewiring or larger conductor sizes are expected. Both share the same mounting footprint and current ratings.

MPN