Skip to main content
Siemens 3RT1016-2BE42 — Contactors

Siemens SIRIUS 3RT1016-2BE42 Power Contactor, Size S00, 24 V

MPN3RT1016-2BE42

Siemens SIRIUS, Size S00 power contactor, 3RT1016-2BE42, 24 V DC coil, 10 A rated at 24 V, spring-loaded terminals, 45 mm width, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2BE42 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2BE42 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2BE42 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1016-2BE42 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2BE42 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2BE42 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2BE42 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2BE42 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2BE42 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

The Siemens SIRIUS 3RT1016-2BE42 is a Size S00 power contactor with a 24 V DC coil, rated to switch 10 A at 24 V in AC-12 duty. The main circuit uses spring-loaded terminals accepting 2x (0.25 to 2.5 mm²) solid or stranded conductors, or 2x (24 to 14 AWG). This eliminates the need for screwdriver torque checks during panel assembly — a time-saver on high-density DIN rails. Rated for motor loads: 4.5 kW at 500 V and 5.5 kW at 690 V (AC-3 duty).

If your application involves frequent reversing or jogging, the AC-4 figure governs contact life, not the AC-3 number. DC switching capability is specified per voltage: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V. These are resistive-load values; inductive DC loads (brake coils, solenoid valves) require a free-wheel diode across the load to prevent contact welding. The coil itself draws 3.3 W closing and 3.3 W holding — a constant-power coil that stays cool in continuous duty. Type 1 coordination allows a 35 A gL/gG fuse. Type 2 means the contactor remains usable after a fault (no welding of main contacts), while Type 1 allows contact replacement. For critical process lines, spec the Type 2 fuse.

Panel Integration and Environmental Limits

At 45 mm wide, 60 mm tall, and 73 mm deep, the 3RT1016-2BE42 occupies a single 45 mm DIN-rail module. The IP20 front protection means it is safe for finger contact in enclosed panels; the terminal area is also IP20. Pollution degree 3.

Frequently asked questions

What is the depth of the 3RT1016-2BE42?

The depth is 73 mm, with a width of 45 mm and height of 60 mm.

What wire size does the spring terminal accept?

The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG).

MPN