Siemens 3RT1016-2BG41 — Contactors

Siemens 3RT1016-2BG41 SIRIUS Contactor, S00, 4 kW AC-2 at 40

MPN3RT1016-2BG41

Siemens SIRIUS power contactor, size S00, order code 3RT1016-2BG41, 4 kW AC-2 at 400 V, 10 A AC-12 max, spring-loaded terminals, current production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2BG41 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2BG41 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2BG41 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1016-2BG41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2BG41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2BG41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2BG41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2BG41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2BG41 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

For AC-3 (squirrel-cage motor starting), the power rating is 4.5 kW at 500 V and 5.5 kW at 690 V, which covers a 7.5 hp motor on a 480 V system. The AC-4 inching/plugging rating is 8.5 A at 400 V, so if your application does frequent reversing or jogging, that's the current limit per operation. The maximum operating current in AC-12 (resistive load) is 10 A, which is the ceiling for general-purpose switching of heaters or lighting banks. The main circuit uses spring-loaded terminals accepting 2x (0.25... 2.5 mm²) solid or stranded, or 2x (24... 14) AWG — no screw torque to verify, which saves time on the wireman's side.

Coil and Control Circuit Details

The auxiliary contact block has one instantaneous contact (NO or NC depending on variant).

This matters when you're specifying the branch circuit protection for a motor starter combination.

Side-by-side mounting is permitted with 6 mm spacing at the side, so you can pack contactors tightly on the rail.

Frequently asked questions

What is the closest functional alternative to the 3RT1016-2BG41?

The 3RT1015-1BB42 is a smaller-frame S00 contactor but with screw terminals instead of spring-loaded. The 3RT1017-1AP01 is a larger-frame S0 contactor with higher ratings. Neither is a direct drop-in replacement without checking the coil voltage and terminal type.

What conductor sizes does the spring-loaded terminal accept?

It accepts 2x (0.25... 2.5 mm²) solid or stranded, or 2x (24... 14) AWG. No screw torque specification is needed.

Will the 3RT1016-2BG41 drop into a panel designed for the 3RT1015-1BB42?

Both are S00 frame size on the same DIN rail footprint, so the physical mounting is identical. However, the 3RT1015-1BB42 uses screw terminals for the main circuit, while this unit uses spring-loaded terminals. The wiring method differs, but the rail position and auxiliary contact layout are compatible.