Siemens 3RT1016-2BM41 — Contactors

Siemens 3RT1016-2BM41 SIRIUS Power Contactor, 10 A AC-12, Si

MPN3RT1016-2BM41

Siemens SIRIUS 3RT1016-2BM41 power contactor, size S00, 1 NO instantaneous contact, spring-loaded terminals, 24 VDC coil, 10 A AC-12, 4.5 kW at 500 V AC-3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2BM41 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2BM41 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2BM41 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1016-2BM41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2BM41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2BM41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2BM41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2BM41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2BM41 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Rated for AC-3 duty at 4.5 kW on 500 V and 5.5 kW on 690 V, it handles three-phase induction motors driving pumps, conveyors, and fans. The AC-2 rating of 4 kW at 400 V covers slip-ring motor starting, while AC-4 at 8.5 A on 400 V suits reversing or inching applications. The coil is a 24 VDC type with a pickup threshold of 0.85 x rated voltage and a dropout of 1.1 x rated voltage, drawing 3.3 W during both closing and holding. This low holding power reduces heat buildup in dense panels.

The AC-12 rating of 10 A maximum operating current defines its resistive load capability — useful for heater banks or transformer primary switching. The AC-3 motor ratings at 4.5 kW (500 V) and 5.5 kW (690 V) are the figures to match against your motor nameplate for full-voltage starting. Spring-loaded terminals on the main circuit accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG). The side clearance of 6 mm allows side-by-side mounting without derating, saving rail space in high-density layouts. Fuse coordination: type 1 requires a 35 A gL/gG fuse, type 2 requires a 20 A gL/gG fuse. This lets you balance fault protection against component survival after a short circuit.

Frequently asked questions

What are the key ratings for this contactor?

AC-3 motor power: 4.5 kW at 500 V, 5.5 kW at 690 V. AC-12 resistive: 10 A. Coil: 24 VDC, 3.3 W. Mechanical endurance: 30 million cycles. Frame size S00.

What wire sizes does the spring-loaded terminal accept?

The main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG).

What is the depth of the 3RT1016-2BM41?

The depth is 73 mm, with a width of 45 mm and height of 60 mm.

Can this contactor be mounted side-by-side?

Yes, side-by-side mounting is allowed with a 6 mm side clearance, and no derating is required for adjacent units.