Skip to main content
Siemens 3RT1016-2EF04-0KS0-ZX95 — Contactors

Siemens 3RT1016-2EF04-0KS0-ZX95 SIRIUS Power Contactor, S00,

MPN3RT1016-2EF04-0KS0-ZX95

Siemens SIRIUS power contactor, size S00, 24 VDC coil, spring-loaded terminals, 10 A at 24 V, 8.5 A AC-4 at 400 V, 45 mm wide, depth 114 mm, screw and snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1016-2EF04-0KS0-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT1016-2EF04-0KS0-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1016-2EF04-0KS0-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1016-2EF04-0KS0-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1016-2EF04-0KS0-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1016-2EF04-0KS0-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1016-2EF04-0KS0-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1016-2EF04-0KS0-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1016-2EF04-0KS0-ZX95 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth114 mm

Product details

It carries a 24 VDC coil and spring-loaded terminals for the main current circuit, rated 10 A at 24 V and 8.5 A in AC-4 duty at 400 V.

For resistive loads (AC-1) the limit is higher, but for motor switching the AC-4 number governs the real-life service life. The coil operates at 24 VDC with a rated current of 10 A at 24 V. The integrated RC surge suppressor means you don't need an external snubber for the coil, which simplifies wiring and reduces panel clutter. Spring-loaded terminals accept 2x (0.25... 2.5 mm²) solid or stranded wire — that's up to 14 AWG, enough for most control and small power circuits. The IP20 finger-safe protection on the front and terminals means it's safe for open-panel mounting without additional shrouding.

The 3RT1016-2EF04-0KS0-ZX95 is a fast mover for MRO and panel-build applications. Keep it on the shelf as a critical spare for any 24 VDC contactor requirement in size S00.

Integration notes

Size S00 means a 45 mm width and 114 mm depth — fits standard 45 mm-wide DIN-rail slots. Side-by-side mounting is allowed, with a minimum 6 mm gap to adjacent devices for heat dissipation. For short-circuit protection, the manufacturer specifies a gL/gG fuse rated 20 A (type of coordination 2). That's the fuse size to order alongside the contactor if you need coordinated protection.

Frequently asked questions

Where can I buy 3RT1016-2EF04-0KS0-ZX95 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What is the closest functional second-source to 3RT1016-2EF04-0KS0-ZX95?

The 3RT1016-1AG61 is a peer in the same SIRIUS S00 family, but it uses screw terminals instead of spring-loaded terminals. If your panel is wired for spring-clamp connections, the -2EF04-0KS0-ZX95 is the direct fit; the -1AG61 would require rewiring the main circuit terminals.

What is the depth of this contactor?

The depth is 114 mm, which is standard for the S00 frame size.

What wire size does the spring-loaded terminal accept?

It accepts 2x (0.25... 2.5 mm²) solid or stranded, equivalent to 2x (24... 14 AWG).

Will 3RT1016-2EF04-0KS0-ZX95 drop into a panel specified for 3RT1016-1AG61 without rewiring?

No, because the -2EF04-0KS0-ZX95 uses spring-loaded terminals while the -1AG61 uses screw terminals. The mounting footprint and DIN-rail clip are identical, but the wiring method differs — you would need to re-terminate the conductors.

MPN
3RT1016-2EF04-0KS0-ZX95