Skip to main content
Siemens 3RT1017-1AB02-1AA0 — Contactors

Siemens 3RT1017-1AB02-1AA0 SIRIUS Power Contactor, S00, 24 V

MPN3RT1017-1AB02-1AA0

Siemens SIRIUS power contactor, size S00, 3RT1017-1AB02-1AA0, 24 V AC 50/60 Hz coil, screw-type terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-1AB02-1AA0 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-1AB02-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-1AB02-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1017-1AB02-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-1AB02-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-1AB02-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1017-1AB02-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1017-1AB02-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-1AB02-1AA0 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It mounts via screw or snap-on onto a 35 mm DIN rail per EN 50022, occupying 45 mm of panel width with a depth of 72 mm and height of 57.5 mm.

Rated for AC-2 duty at 400 V delivering 5.5 kW, and AC-4 at 400 V carrying 8.5 A — these are the motor-switching numbers that govern real-world selection. The 24 V AC coil (50/60 Hz) pulls in at 0.8...1.1 x rated voltage, so it holds reliably on a nominal 24 V supply but drops out cleanly below about 19 V, preventing contactor chatter on a sagging line. Auxiliary contact ratings cover control-circuit switching: 10 A at 24 V, 6 A at 230 V, and 0.3 A at 220 V DC — enough for PLC inputs or relay coils in the same panel. The main circuit uses screw-type terminals accepting 2x (0.5...1.5 mm²) solid or 2x (0.75...2.5 mm²) stranded, with a maximum of 2x (0.75...4 mm²) — no special crimping tool needed for standard panel wiring. Short-circuit coordination is specified: Type 2 coordination requires a gL/gG 20 A fuse; Type 1 allows up to 35 A.

Integration into a Panel

The front face carries IP20 — finger-safe for a closed panel — and the terminals are also IP20, meaning no additional touch protection required inside the enclosure.

Frequently asked questions

What are the key motor-switching ratings?

It switches 5.5 kW at 400 V under AC-2 duty, and 8.5 A at 400 V under AC-4 duty — these are the ratings that determine motor load fit.

What is the mounting footprint?

Width 45 mm, height 57.5 mm, depth 72 mm. Snaps onto 35 mm DIN rail per EN 50022, with side-by-side mounting allowed at 6 mm spacing.

What wire sizes does the main circuit accept?

Screw terminals accept 2x (0.5...1.5 mm²) solid, 2x (0.75...2.5 mm²) stranded, up to max 2x (0.75...4 mm²).

What fuse coordination is required?

Type 2 coordination needs a gL/gG 20 A fuse; Type 1 allows up to 35 A.

What is the operating temperature range?

-25 °C to +60 °C during operation.

MPN
3RT1017-1AB02-1AA0