Siemens 3RT1017-1AB02-ZW98 — Contactors

Siemens 3RT1017-1AB02-ZW98 SIRIUS Power Contactor, S00, 24 V

MPN3RT1017-1AB02-ZW98

Siemens SIRIUS 3RT1017-1AB02-ZW98 power contactor, size S00, 24 V 50/60 Hz coil, 5.5 kW at 400 V AC-3, screw terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-1AB02-ZW98 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-1AB02-ZW98 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-1AB02-ZW98 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1017-1AB02-ZW98 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-1AB02-ZW98 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-1AB02-ZW98 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1017-1AB02-ZW98 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1017-1AB02-ZW98 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-1AB02-ZW98 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It's a 24 V 50/60 Hz AC coil contactor rated for 5.5 kW at 400 V in AC-3 duty (motor starting), and also carries a 5.5 kW rating at 690 V AC-3. For heavy-duty jogging or inching (AC-4), it's rated at 8.5 A at 400 V. The S00 frame is the smallest in the SIRIUS contactor family, measuring 45 mm wide, 57.5 mm tall, and 72 mm deep. That compact footprint fits tightly packed DIN-rail enclosures where every millimeter of rail space counts.

Side-by-side mounting is permitted with 6 mm spacing to the side, which helps when populating a multi-contactor row without wasting panel width. Main circuit terminals are screw-type, accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12. The front of the terminal has IP20 finger protection, so it's safe for open-panel work as long as the front cover is on.

Coil and operating conditions

The coil is rated for 24 V at both 50 Hz and 60 Hz, with an operating range of 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz.

Protection and coordination

This matters when designing a panel for selectivity or when the upstream protection is already fixed.

Frequently asked questions

What are the key ratings for this contactor?

It is a 24 V 50/60 Hz AC coil contactor rated for 5.5 kW at 400 V AC-3 and 5.5 kW at 690 V AC-3. AC-4 rating is 8.5 A at 400 V. The S00 frame size measures 45 x 57.5 x 72 mm.

What wire sizes does the screw terminal accept?

Main circuit terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12.

What are the fuse coordination requirements?

For type 2 coordination, use a gL/gG fuse rated 20 A. For type 1 coordination, the fuse can be 35 A.