Siemens 3RT1017-1AP02-ZW96 SIRIUS Power Contactor, Size S00,

MPN3RT1017-1AP02-ZW96

Siemens SIRIUS power contactor, Size S00, 24 VDC coil, 45 mm wide, screw terminals, 5.5 kW at AC-2 400 V, 10 A rated operational current at AC-12.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-1AP02-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-1AP02-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-1AP02-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1017-1AP02-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-1AP02-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-1AP02-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1017-1AP02-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1017-1AP02-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-1AP02-ZW96 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It carries a 24 VDC coil and is rated for 5.5 kW at AC-2 duty on a 400 V supply, making it a direct fit for moderate motor control applications in industrial automation. Mechanical life is 30,000,000 cycles.

Ratings and Coordination

The 3RT1017-1AP02-ZW96 is rated for AC-2 duty at 5.5 kW at 400 V, covering slip-ring motor loads, and AC-4 duty at 8.5 A at 400 V for plugging and inching applications. For resistive loads (AC-12), the maximum operating current is 10 A. Short-circuit coordination is specified: Type 2 coordination requires a gL/gG fuse rated 20 A, while Type 1 coordination allows a 35 A gL/gG fuse. This lets the panel designer balance protection level against fuse size depending on the downstream load and fault current capability. The main circuit uses screw-type terminals accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded conductors, with AWG equivalents of 2x (20 to 16), 2x (18 to 14), and 1x 12.

Integration Notes

Side-by-side mounting permitted with 6 mm clearance. The coil operates at 50/60 Hz with a voltage tolerance of 0.8 to 1.1 at 50 Hz and 0.85 to 1.1 at 60 Hz, ensuring reliable pick-up across typical line variations.

Frequently asked questions

Will 3RT1017-1AP02-ZW96 drop into a panel specified for 3RT1017-1AP01?

Both share the same Size S00 frame, 45 mm width, and DIN rail mounting, so the physical fit and wiring footprint are identical. The -ZW96 suffix indicates a special version; verify the coil voltage and any accessory differences against your BOM before substitution.