Siemens 3RT1017-1AT61 — Contactors

Siemens 3RT1017-1AT61 SIRIUS Power Contactor, 3-Pole, 5.5 kW

MPN3RT1017-1AT61

Siemens SIRIUS 3RT1017-1AT61 power contactor, size S00, 3-pole, 5.5 kW at 400 V AC-2, 8.5 A AC-4, screw terminals, snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-1AT61 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-1AT61 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-1AT61 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1017-1AT61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-1AT61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-1AT61 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1017-1AT61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1017-1AT61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-1AT61 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It carries three normally-open main contacts and no normally-closed main contacts, so it is a straight three-pole make device — typical for three-phase motor circuits where you only need to close the power path. Rated for AC-2 duty at 5.5 kW on 400 V, it handles slip-ring motor starting and braking. For AC-4 duty (plugging, inching) it is rated 8.5 A at 400 V — that is the current that governs the contactor's life under frequent reversals or jogging, not the AC-2 figure. The auxiliary contact block (integrated) switches 10 A at 24 V, 6 A at 230 V, and 0.3 A at 220 V DC — the DC ratings are the ones to watch if you are switching a PLC output or a DC brake coil; the inductive DC load will arc longer than the AC equivalent.

Front face carries IP20 finger protection; the terminals are also IP20.

Main contact ratings: 5.5 kW at 400 V AC-2, 5.5 kW at 690 V AC-2, 8.5 A at 400 V AC-4. Auxiliary contact: 10 A at 24 V AC-12, 6 A at 230 V, 2 A at 60 V DC, 0.3 A at 220 V DC. Operating temperature: -25 to +60 °C. Maximum operating altitude: 2 000 m. Terminal capacity: screw-type terminals accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid/stranded, plus 1x 12 AWG. Short-circuit protection: fuse gL/gG 20 A for type 2 coordination, 35 A for type 1.

Frequently asked questions

What is the depth of 3RT1017-1AT61?

72 mm.

What wire sizes does the terminal accept?

Screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded, plus 1x 12 AWG.