Siemens 3RT1017-1AT62 SIRIUS Power Contactor, S00, 3 NO, 24

MPN3RT1017-1AT62

Siemens SIRIUS, power contactor, 3RT1017-1AT62, size S00, 3 NO main contacts, 24 VDC coil, 10 A rated, screw terminals, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-1AT62 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-1AT62 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-1AT62 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1017-1AT62 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-1AT62 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-1AT62 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1017-1AT62 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1017-1AT62 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1017-1AT62 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It's a current-production part, so no lifecycle scramble; this is what you spec into a new panel or drop in as a line-down spare for an existing S00 footprint.

Motor duty and coordination — the real selection numbers

For AC-4 (plugging/reversing/inching) at 400 V, the rated operational current is 8.5 A. These are the numbers that govern contact life, not the 10 A AC-12 resistive rating. Type 1 coordination requires a 35 A gL/gG fuse; type 2 coordination needs a 20 A gL/gG fuse. If you're coordinating with a motor starter or overload relay, the 20 A type 2 limit is the one that keeps the contactor re-usable after a fault.

Both main and auxiliary/control circuits use screw-type terminals. The main contacts accept 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), or max 2x (0.75...4 mm²) solid or stranded — same ranges for the auxiliary contacts. AWG equivalents are 2x (20...16), 2x (18...14), and 1x 12. The 72 mm depth, 45 mm width, and 57.5 mm height fit a shallow backpanel.

Storage temperature exceeds that range — the handling limit, not the running limit. RoHS compliance date is 01.07.2006, so it meets the original EU RoHS directive. Electrical life depends on the switching category and current; at AC-2 5.5 kW you'll get a fraction of that, but still well into the millions for most conveyor or pump cycling rates.