Siemens 3RT1017-1AW21 SIRIUS S00 Power Contactor, 10 A, 24 V

MPN3RT1017-1AW21

Siemens SIRIUS S00 power contactor, 3RT1017-1AW21, 10 A at 24 V DC, screw-type terminals, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-1AW21 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-1AW21 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-1AW21 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz480 V
3RT1017-1AW21 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-1AW21 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-1AW21 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1017-1AW21 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1017-1AW21 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-1AW21 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

S00 frame, 24 V DC coil, screw terminals

Rated operating current hits 10 A at AC-12 (resistive loads) and 8.5 A at AC-4 (frequent starting/inching) at 400 V.

Coordination and wiring

For Type 1 coordination (no damage but may need contact replacement after a fault) the required fuse is gL/gG 35 A. This lets you match the protection scheme to your maintenance philosophy. Screw terminals accept solid or stranded conductors: 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or max 2x (0.75–4 mm²). AWG equivalents are 2x (20–16), 2x (18–14), or 1x 12. The IP20 finger-safe protection on the front and terminals means it's safe for open-panel work as long as the enclosure is locked.

Frequently asked questions

How do I get current pricing and availability for 3RT1017-1AW21?