Siemens 3RT1017-2AH02 SIRIUS Power Contactor, S00 Frame, 5.5

MPN3RT1017-2AH02

Siemens SIRIUS power contactor, size S00, 3RT1017-2AH02, 5.5 kW at 400 V AC-2, 45 mm wide, spring-loaded terminals, DIN EN 50022 snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-2AH02 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-2AH02 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-2AH02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz48 V
3RT1017-2AH02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-2AH02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-2AH02 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1017-2AH02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1017-2AH02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-2AH02 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Depth is 73 mm, height 60 mm — check enclosure clearance before wiring, especially if using deep terminal shrouds.

Ratings and load capability

In AC-4 (plugging/reversing) at 400 V it handles 8.5 A. For DC switching at 24 V it's rated 10 A, dropping to 0.3 A at 220 V DC. The main circuit uses spring-loaded terminals accepting 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG).

Pollution degree 3 rating suits industrial environments with conductive contamination.

Frequently asked questions

What are the key dimensions for panel layout?

Width 45 mm, height 60 mm, depth 73 mm. It mounts on 35 mm DIN rail per DIN EN 50022 via screw or snap-on.

What wire sizes does the spring-loaded terminal accept?

The main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG).

What fuse rating is required for type 2 coordination?

For type 2 coordination (no damage to the contactor), use a gL/gG 20 A fuse upstream. Type 1 coordination allows 35 A gL/gG.