Skip to main content
Siemens 3RT1017-2AV02 — Contactors

Siemens 3RT1017-2AV02 SIRIUS Power Contactor, 45mm, Spring-L

MPN3RT1017-2AV02

Siemens SIRIUS power contactor, size S00, 3RT1017-2AV02, spring-loaded terminals, 45 mm width, screw and snap-on mounting on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-2AV02 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-2AV02 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-2AV02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RT1017-2AV02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-2AV02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-2AV02 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1017-2AV02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1017-2AV02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-2AV02 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Spring-loaded terminals on the main current circuit accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). No screwdriver needed for the power connections — good for quick swaps in a live panel if the line's down.

Ratings that matter for the panel

The contactor carries motor loads: at AC-2 duty at 400 V it's rated for 5.5 kW, and at AC-4 at 400 V the operating current is 8.5 A. For resistive loads (AC-12), the maximum operating current is 10 A at 24 V. The DC switching ratings drop off fast: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V — so if you're switching DC solenoids, watch the voltage curve.

Side-by-side mounting is permitted, which saves rail space when you need multiple contactors in a row. The front has IP20 finger protection; the terminals also carry IP20.

Frequently asked questions

What is the closest functional second-source to 3RT1017-2AV02?

The 3RT1017-1AP01 is a peer in the same SIRIUS S00 frame, but it uses screw terminals instead of spring-loaded terminals. If your panel is wired for screw clamps, the 1AP01 drops in without rewiring the main circuit — same footprint, same DIN rail mount, same coil voltage class. The 2AV02's spring-loaded terminals save time on assembly but require ferruled or solid wire prepared for a cage clamp.

What is the depth of 3RT1017-2AV02?

73 mm, which fits standard shallow enclosures and leaves room for auxiliary contact blocks mounted on the front.

What wire sizes does the spring-loaded terminal accept?

Solid or stranded: 2x (0.25 to 2.5 mm²) or 2x (24 to 14 AWG). Strip length is not listed here, but standard spring-clamp practice is 8-10 mm.

MPN
3RT1017-2AV02