Skip to main content
Siemens 3RT1017-2HB41 — Contactors

Siemens 3RT1017-2HB41 SIRIUS Power Contactor, 24 V DC, S00

MPN3RT1017-2HB41

Siemens SIRIUS power contactor, 3RT1017-2HB41, size S00, 24 V DC coil, 5.5 kW at 400 V AC-2, spring-loaded terminals, IP20, screw and snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-2HB41 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-2HB41 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-2HB41 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1017-2HB41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-2HB41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-2HB41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1017-2HB41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RT1017-2HB41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-2HB41 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

SIRIUS S00 power contactor, 24 V DC coil — what fits and what doesn't

Its 24 V DC coil draws 2.3 W to close and holds at the same 2.3 W — a steady-state power figure that matters for DC supply sizing and heat buildup inside a sealed enclosure. The spring-loaded terminals on the main circuit accept 2x (0.25 to 2.5 mm²) solid or stranded wire — no screwdriver needed for terminations, which speeds up panel wiring and reduces torque-verification steps.

Coil and auxiliary contact ratings

The 24 V DC coil has a closing power and holding power both rated at 2.3 W. That flat power curve simplifies the DC supply budget — no inrush spike to design around. One instantaneous auxiliary contact is built in (NO/NC configuration not specified in the base data).

Frequently asked questions

Where can I buy 3RT1017-2HB41 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ to confirm current availability and pricing at quote time.

What is 3RT1017-2HB41's listed depth?

The depth is 73 mm, which fits standard S00 contactor depth profiles for DIN-rail enclosures.

What wire sizes do the spring-loaded terminals accept?

The main circuit spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded conductors, or 2x (24 to 14 AWG).

What is the AC-2 motor rating at 400 V?

Rated 5.5 kW at 400 V for AC-2 duty — suited for wound-rotor motor switching in moderate-duty applications.

MPN