Skip to main content
Siemens 3RT1017-2VB41 — Contactors

Siemens 3RT1017-2VB41 SIRIUS Power Contactor, S00, 24 VDC, 5

MPN3RT1017-2VB41

Siemens SIRIUS power contactor, size S00, 3RT1017-2VB41, 24 VDC coil with integrated diode suppression, 5.5 kW at 400 V AC-3, spring-loaded terminals, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1017-2VB41 — Identification
ParameterValue
Contactor frame sizeS00
3RT1017-2VB41 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V5.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1017-2VB41 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1017-2VB41 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1017-2VB41 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 35 A
Short-circuit coordination type 2, fusefuse gL/gG: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1017-2VB41 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1017-2VB41 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
3RT1017-2VB41 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1017-2VB41 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

Rated for 5.5 kW at 400 V AC-3 (the standard motor-switching duty class), this contactor handles typical three-phase induction motors up to that power. The 24 VDC coil draws 1.4 W holding power and includes a built-in diode surge suppressor — no external flyback diode needed on the control side. For short-circuit protection with type 2 coordination (minimal damage to the contactor), use a gL/gG fuse rated 20 A. The operating temperature range is -25 to +60 °C, and the front face carries IP20 protection — suitable for enclosed panel mounting, not washdown areas.

MPN
3RT1017-2VB41