Siemens 3RT1023-1AT60 — Contactors

Siemens 3RT1023-1AT60 SIRIUS Power Contactor, S0, 4 kW AC-2

MPN3RT1023-1AT60

Siemens SIRIUS power contactor, 3RT1023-1AT60, size S0, 3-pole, screw terminals, 4 kW at AC-2 400 V, 24 VDC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1023-1AT60 — Identification
ParameterValue
Contactor frame sizeS0
3RT1023-1AT60 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1023-1AT60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1023-1AT60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1023-1AT60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1023-1AT60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1023-1AT60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1023-1AT60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1023-1AT60 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth91 mm

Product details

It carries three normally-open main contacts and is rated for 4 kW at AC-2 duty at 400 V, which covers slip-ring motor starting and plugging applications. For resistive loads (AC-12), it handles up to 10 A.

The 45 mm width and 85 mm height fit standard panel layouts; depth is 91 mm. Front face carries an IP20 rating; the terminals themselves are IP00, so live parts are exposed — keep the panel door interlocked or use a finger-safe cover.

Wiring and conductor sizing

Main circuit terminals are screw-type, accepting solid conductors from 2x 0.5 mm² up to 2x 4 mm², and stranded from 2x 1 mm² up to 2x 10 mm². For AWG, that's 2x 16–12 solid or 2x 14–10 stranded, with a single 8 AWG maximum.

For Type 2 coordination (contactor remains usable after a fault), the fuse must be limited to 25 A gL/gG. This matters when you're designing for minimal downtime — Type 2 keeps the line running after a short-circuit event without swapping the contactor.

Frequently asked questions

What is the closest functional alternative — the 3RT1023-1AL20?

The 3RT1023-1AL20 is the same SIRIUS S0 contactor with the same AC-2 and AC-4 ratings, but with an AC coil instead of the 24 VDC coil on the 1AT60. They share the same footprint, terminal layout, and mounting rail. If your control voltage is 24 VDC, the 1AT60 is the correct choice; if you have an AC control supply, the 1AL20 drops in without rewiring the power circuit.

What is the depth of the 3RT1023-1AT60?

The depth is 91 mm. This is the dimension from the mounting rail to the furthest front projection, including the terminals.

What conductor sizes does the 3RT1023-1AT60 accept?

Solid conductors: 2x 0.5–1.5 mm², 2x 0.75–2.5 mm², max 2x 0.75–4 mm². Stranded: 2x 1–2.5 mm², 2x 2.5–6 mm², max 2x 10 mm². AWG equivalents: 2x 16–12 solid, 2x 14–10 stranded, single 8 AWG max.

Will the 3RT1023-1AT60 drop into a panel wired for the 3RT1023-1AL20?

Yes, mechanically and electrically on the power side. Both are S0 frame, same DIN-rail footprint, same terminal positions. The only difference is the coil: the 1AT60 is 24 VDC, the 1AL20 is AC. If your panel has a 24 VDC control supply, the 1AT60 is a direct swap. If the control circuit is AC, you would need to change the coil supply or use the 1AL20.

MPN
3RT1023-1AT60