Siemens 3RT1023-3AT60 — Contactors

Siemens 3RT1023-3AT60 SIRIUS Power Contactor, S0, 3 NO, 24 V

MPN3RT1023-3AT60

Siemens SIRIUS power contactor, size S0, 3 NO main contacts, 24 VDC coil, screw-type terminals, 45 mm width, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1023-3AT60 — Identification
ParameterValue
Contactor frame sizeS0
3RT1023-3AT60 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1023-3AT60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1023-3AT60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1023-3AT60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1023-3AT60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1023-3AT60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1023-3AT60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1023-3AT60 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth90 mm

Product details

SIRIUS S0 power contactor — 3RT1023-3AT60

Rated for AC-3 duty at 4.5 kW at 500 V and 5.5 kW at 690 V, it handles typical three-phase induction motor loads in conveyor, pump, and fan applications. Front-side protection is IP20 (finger-safe), while the terminals themselves are IP00 — standard for screw-clamp contactors.

The 45 mm wide S0 footprint occupies a single DIN-rail position. Side-by-side mounting is permitted with zero clearance between units, saving rail space in dense panels. The 6 mm clearance to grounded metal on the side is the only mandatory air gap. Main circuit terminals accept screw-clamp connections: 2x (1–2.5 mm²) solid/stranded, 2x (2.5–6 mm²), or up to 2x 10 mm². AWG equivalents are 2x (16–12), 2x (14–10), or 1x 8. Auxiliary contact wiring uses 2x (0.25–2.5 mm²) solid.

For BOM freeze or second-source planning, the 3RT1023-3AT60 is a direct form-fit-function match for other S0-frame 3RT1023 variants with the same coil voltage. The screw-terminal main circuit and 3 NO contact configuration are the key fit parameters.

Type 2 coordination (contactor remains fully serviceable) requires a 25 A gL/gG fuse. These values guide the selection of branch circuit protection.

Frequently asked questions

What are the main contact ratings for 3RT1023-3AT60?

It has three normally-open main contacts. AC-3 motor power is 4.5 kW at 500 V and 5.5 kW at 690 V. AC-4 reversing duty is rated at 8.5 A at 400 V.

What is the coil voltage for this contactor?

The coil is rated at 24 VDC.

Where can I buy 3RT1023-3AT60 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3RT1023-3AT60 drop into a panel specified around 3RT1023-1AL20?

Both are S0-frame contactors with the same 45 mm width and DIN-rail mounting, so the mechanical fit is identical. However, verify the coil voltage and main contact configuration match your circuit — the -3AT60 uses a 24 VDC coil and 3 NO main contacts.

MPN