Siemens 3RT1023-3AV60 — Contactors

Siemens 3RT1023-3AV60 SIRIUS Power Contactor, 3 NO, 60 Hz

MPN3RT1023-3AV60

Siemens SIRIUS 3RT1023-3AV60 power contactor, size S0, 3 NO main contacts, screw-type terminals, 60 Hz rated, IP20 front, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1023-3AV60 — Identification
ParameterValue
Contactor frame sizeS0
3RT1023-3AV60 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V4.5 kW
Rated value @ 690 V5.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1023-3AV60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1023-3AV60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1023-3AV60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1023-3AV60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1023-3AV60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1023-3AV60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1023-3AV60 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth90 mm

Product details

Lead — integrator note

AC-4 at 400 V is 8.5 A, for reversing or inching duty. At 690 V the contactor handles 5.5 kW (AC-3). Pollution degree 3 means it tolerates conductive dust in industrial enclosures.

Coordination and wiring

For type 1 coordination (device may be damaged but safe), use 63 A. Main circuit terminals accept 2x (0.25 to 2.5 mm²) solid or 2x (1 to 2.5 mm²) stranded, up to 2x 10 mm². AWG equivalents are 2x (16 to 12) solid, 2x (14 to 10) stranded, or 1x 8.

Frequently asked questions

Where can I buy 3RT1023-3AV60 and how do I get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ; availability and current pricing are confirmed at quote time.

What is 3RT1023-3AV60's listed depth?

The depth is 90 mm.

What wire sizes does the main circuit accept?

Solid wire: 2x (0.25 to 2.5 mm²); stranded: 2x (1 to 2.5 mm²); maximum 2x 10 mm². AWG equivalents: 2x (16 to 12) solid, 2x (14 to 10) stranded, or 1x 8.

Will 3RT1023-3AV60 drop into a panel specified around 3RT1023-1AL20 without rewiring?

Both are size S0 contactors with the same DIN-rail footprint and screw-terminal layout, so mechanical fit is identical. The 3RT1023-3AV60 is a 60 Hz variant; the 3RT1023-1AL20 is 50 Hz. Check the coil voltage and auxiliary configuration — the main contact block and terminal spacing are the same.

MPN
3RT1023-3AV60