Siemens 3RT1024-1AC20-ZW96 — Contactors

Siemens SIRIUS 3RT1024-1AC20-ZW96 Power Contactor, 7.5 kW at

MPN3RT1024-1AC20-ZW96

Siemens SIRIUS 3RT1024-1AC20-ZW96 power contactor, S0 frame, 7.5 kW at 500 V/690 V, AC-4 12.5 A at 400 V, 45 mm width, IP20 front, screw terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1024-1AC20-ZW96 — Identification
ParameterValue
Contactor frame sizeS0
3RT1024-1AC20-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V12.5 A
Rated value @ 400 V3 A
Rated value @ 500 V7.5 kW
Rated value @ 690 V7.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1024-1AC20-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1024-1AC20-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1024-1AC20-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1024-1AC20-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1024-1AC20-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1024-1AC20-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1024-1AC20-ZW96 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth91 mm

Product details

The AC-12 maximum operating current of 10 A applies to resistive loads like heater banks or control transformers.

Auxiliary contact capacity

The built-in auxiliary contacts are rated for 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V. For DC switching, the ratings drop to 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — typical for PLC inputs or signal lamps. Keep the DC voltage below 60 V for full 2 A capacity; above that, the arc extinguishes less efficiently.

Main power terminals accept solid conductors from 0.5 to 4 mm² (two per clamp) and stranded from 1 to 10 mm² (two per clamp). AWG equivalents are 2x 16–12 solid, 2x 14–10 stranded, and 1x 8. Mechanical life is 10 million cycles — the contactor itself is not the weak link in most duty cycles.

Frequently asked questions

What are the key ratings for this contactor?

Motor power: 7.5 kW at 500 V and 690 V. AC-4 current: 12.5 A at 400 V. AC-2 power: 5.5 kW at 400 V. Auxiliary contacts: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V AC; 2 A at 60 V DC, 1 A at 110 V DC, 0.3 A at 220 V DC. Mechanical life: 10 million cycles.

What fuse do I need for Type 2 coordination?

For Type 2 coordination (no damage after a short circuit), use a gL/gG 25 A fuse upstream. For Type 1 coordination (contactor may be sacrificial), use a gL/gG 63 A fuse.

What is the mounting and wiring specification?

Mounts on 35 mm DIN rail per EN 50022 via screw or snap-on. Width is 45 mm, height 85 mm, depth 91 mm. Main terminals accept solid 0.5–4 mm² (2x per clamp) and stranded 1–10 mm² (2x per clamp). AWG: 2x 16–12 solid, 2x 14–10 stranded, 1x 8.

MPN
3RT1024-1AC20-ZW96