Siemens 3RT1024-1AD20 — Contactors

Siemens 3RT1024-1AD20 SIRIUS Power Contactor, S0, 7.5 kW at

MPN3RT1024-1AD20

Siemens SIRIUS 3RT1024-1AD20 power contactor, size S0, 7.5 kW at 690 V AC-3, screw terminals, 24 VDC coil, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1024-1AD20 — Identification
ParameterValue
Contactor frame sizeS0
3RT1024-1AD20 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V12.5 A
Rated value @ 400 V3 A
Rated value @ 500 V7.5 kW
Rated value @ 690 V7.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1024-1AD20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz42 V
3RT1024-1AD20 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1024-1AD20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1024-1AD20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1024-1AD20 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1024-1AD20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1024-1AD20 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth91 mm

Product details

The AC-3 rating at 400 V is 7.5 kW, and at 690 V it also delivers 7.5 kW — meaning this contactor handles standard 400 V motors up to 7.5 kW and can also switch 690 V motors at the same power, useful in 690 V distribution systems or variable-speed drive output circuits.

Mounting and integration into a panel

The front of the contactor is IP20 (finger-safe), while the terminals are IP00 — so the wiring zone is exposed and requires the panel enclosure for touch protection.

Wiring and conductor sizing

Main circuit screw terminals accept 2x (1 to 2.5 mm²), 2x (2.5 to 6 mm²), or max 2x 10 mm² — fine-stranded or solid. For AWG, that's 2x (16 to 12), 2x (14 to 10), or 1x 8. Auxiliary contacts (if fitted) take 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²). Strip length and torque values are on the nameplate label. For short-circuit protection, Type 2 coordination (no welding on fault) requires a gL/gG fuse of 25 A. Type 1 coordination (welding allowed but no fire risk) allows a 63 A fuse. This matters when specifying the upstream motor protection circuit breaker or fuse holder.

Frequently asked questions

What is the depth of the 3RT1024-1AD20?

The depth is 91 mm, measured from the DIN rail mounting surface to the furthest projection of the contactor body.

What conductor sizes does the 3RT1024-1AD20 accept for the main and auxiliary circuits?

Main circuit terminals accept 2x (1 to 2.5 mm²), 2x (2.5 to 6 mm²), or max 2x 10 mm² (fine-stranded). Auxiliary terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²).