Siemens 3RT1024-1AR60 — Contactors

Siemens 3RT1024-1AR60 SIRIUS Power Contactor, 24 VDC Coil, S

MPN3RT1024-1AR60

Siemens SIRIUS power contactor, 3RT1024-1AR60, Size S0, 24 VDC coil, screw terminals, 45 mm wide, IP20 front, 91 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1024-1AR60 — Identification
ParameterValue
Contactor frame sizeS0
3RT1024-1AR60 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V12.5 A
Rated value @ 400 V3 A
Rated value @ 500 V7.5 kW
Rated value @ 690 V7.5 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1024-1AR60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RT1024-1AR60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1024-1AR60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1024-1AR60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1024-1AR60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1024-1AR60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1024-1AR60 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth91 mm

Product details

The 24 VDC coil holds at nominal and drops out below the undervoltage threshold typical for PLC-driven outputs. Rated for AC-2 duty at 5.5 kW and AC-4 at 12.5 A, both at 400 V, this contactor handles squirrel-cage motor starting and plugging/reversing loads. The screw-type main terminals accept up to 2x 10 mm² stranded or 1x 8 AWG, making it straightforward to land in a mixed-gauge panel.

Switching Ratings and Coordination

The DC switching matrix covers 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — useful for interposing relays or small DC motor brakes. AC-12 resistive switching is rated to 10 A maximum. For motor protection, Type 2 coordination requires a 25 A gL/gG fuse; Type 1 allows up to 63 A. The 400 V AC-2 power rating (5.5 kW) matches a typical 7.5 hp motor at 400 V three-phase.

Side-by-side mounting is permitted with zero spacing, saving DIN rail space; 6 mm clearance is required at the sides for airflow if derating is a concern.

Frequently asked questions

What are the key switching ratings for this contactor?

At 400 V AC-2 duty it is rated for 5.5 kW motor load; AC-4 duty (reversing/plugging) is 12.5 A. DC switching covers 10 A at 24 V down to 0.3 A at 220 V. The coil is 24 VDC.

Will the 3RT1024-1AR60 fit a panel designed for the 3RT1023-1AL20?

Both are S0-frame contactors with the same 45 mm width and 85 mm height, so the footprint matches. The key difference is the coil voltage — the 3RT1024-1AR60 uses 24 VDC, while the 3RT1023-1AL20 uses a different coil voltage. Verify the control circuit voltage before substituting.

How do I get pricing and availability for the 3RT1024-1AR60?

Submit an RFQ through the storefront. This part is sourced through independent distribution channels; current pricing and stock levels are confirmed at quote time.