Siemens 3RT1025-1AB00-ZW95 — Contactors

Siemens 3RT1025-1AB00-ZW95 SIRIUS Power Contactor, 24 V 50 H

MPN3RT1025-1AB00-ZW95

Siemens SIRIUS, power contactor, 3RT1025-1AB00-ZW95, size S0, 3 NO main contacts, 24 V 50 Hz coil, screw terminals, 45 mm width, 85 mm height, 91 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1025-1AB00-ZW95 — Identification
ParameterValue
Contactor frame sizeS0
3RT1025-1AB00-ZW95 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V10 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1025-1AB00-ZW95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1025-1AB00-ZW95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1025-1AB00-ZW95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1025-1AB00-ZW95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1025-1AB00-ZW95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1025-1AB00-ZW95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1025-1AB00-ZW95 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth91 mm

Product details

SIRIUS 3RT1025-1AB00-ZW95 — panel-builder commissioning notes

Size S0 power contactor with three normally-open main contacts. Coil is 24 V at 50 Hz, operating range 0.8 to 1.1 times rated voltage. Rated for AC-2 duty at 7.5 kW at 400 V, and AC-4 at 15.5 A at 400 V — the AC-4 figure governs reversing or plugging applications where the contactor makes and breaks under load. For motor starting (AC-3), the 400 V rating is 10 kW and at 690 V it reaches 11 kW. Terminals are screw-type on the main circuit, accepting 2x (1 to 2.5 mm²) solid/stranded, up to 2x 10 mm² max. Auxiliary contact ratings cover 24 V at 10 A, 110 V at 1 A, 230 V at 6 A, and 400 V at 3 A — enough for pilot-duty control circuits.

Width is 45 mm, height 85 mm, depth 91 mm — the 91 mm depth is the dimension behind the panel face, so verify enclosure depth if using a shallow gland plate. Front face is IP20, terminals are IP00 (finger-safe only when wired and covered). For type 2 coordination (no-weld fault clearing), use gL/gG fuses rated 25 A. The 6 mm side clearance to adjacent devices is the minimum for airflow; side-by-side mounting is permitted but verify heat rise if the panel is sealed.