Siemens 3RT1025-1AC24 SIRIUS Power Contactor, 24 V Coil, S0

MPN3RT1025-1AC24

Siemens SIRIUS 3RT1025-1AC24 power contactor, S0 frame, 24 V 50/60 Hz coil, AC-3 rated 10 kW at 500 V / 11 kW at 690 V, 45 mm width, screw and snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1025-1AC24 — Identification
ParameterValue
Contactor frame sizeS0
3RT1025-1AC24 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V10 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1025-1AC24 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1025-1AC24 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1025-1AC24 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1025-1AC24 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1025-1AC24 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1025-1AC24 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1025-1AC24 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth140 mm

Product details

It's the part you spec into a panel when you need a 24 V AC coil that pulls in reliably on both 50 and 60 Hz supplies, and you want to snap it onto a standard 35 mm DIN rail per EN 50022 without reaching for screws.

The AC-3 motor switching rating is the one that governs the BOM line: 10 kW at 500 V and 11 kW at 690 V. That's the figure you match to your motor nameplate for standard squirrel-cage starting — not the AC-1 resistive current (10 A max) or the AC-4 reversing/inching duty (15.5 A at 400 V), which are lower. The coil is rated 24 V at both 50 Hz and 60 Hz — the operating range spans 0.8 to 1.1 times rated voltage at 50 Hz, and 0.85 to 1.1 at 60 Hz. That means it holds in down to about 19.2 V on a 50 Hz supply, which gives you some headroom for voltage drop on long cable runs in the panel. Pollution degree 3 means this contactor is rated for the conductive dust and humidity you find inside industrial enclosures — not a clean room part. The IP20 front protection keeps fingers out; the IP00 terminals mean those lug connections are live with the cover off, so standard warning labels apply. The 10 million mechanical cycles typical is the no-load endurance; under full AC-3 load, expect derating per the contactor's electrical life curve.

The S0 frame is 45 mm wide and 85 mm tall, so it occupies one standard 45 mm DIN cell. Side-by-side mounting is permitted, which means you can gang several of these on a rail without mandatory spacing gaps — but the 6 mm clearance to grounded metal on the sides still applies for creepage. Main contact terminals accept 2x (0.5 to 1.5 mm²) solid, 2x (0.75 to 2.5 mm²) stranded, or up to 2x 4 mm² max. For AWG, that's 2x (16 to 12) solid, 2x (14 to 10) stranded, or 1x 8. The coil terminals take 2x (1 to 2.5 mm²) or up to 2x 10 mm². Strip length is not listed here, but 8 mm is typical for this terminal class.

Type 1 coordination (welding allowed but no fire risk) takes a 63 A gL/gG fuse. That's your short-circuit protection sizing — not a suggestion, it's what the coordination tests certify.

Frequently asked questions

What are the key motor ratings for this contactor?

AC-3 motor duty: 10 kW at 500 V and 11 kW at 690 V. AC-4 reversing duty: 15.5 A at 400 V. AC-2 slip-ring duty: 7.5 kW at 400 V. The coil is 24 V, rated for both 50 and 60 Hz.

Does this contactor fit on a standard DIN rail?

Yes, it mounts via screw and snap-on onto a 35 mm standard mounting rail per DIN EN 50022. The S0 frame is 45 mm wide and 85 mm tall, occupying one standard DIN cell.

What fuse rating is needed for Type 2 coordination?

Type 2 coordination (no contact welding) requires a gL/gG fuse rated 25 A. Type 1 coordination (welding permitted) uses a 63 A gL/gG fuse.

What wire sizes fit the main and coil terminals?

Main contacts: 2x (0.5 to 1.5 mm²) solid, 2x (0.75 to 2.5 mm²) stranded, max 2x 4 mm². AWG: 2x (16 to 12) solid, 2x (14 to 10) stranded, 1x 8. Coil terminals: 2x (1 to 2.5 mm²) or up to 2x 10 mm².

What compliance documentation comes with this part?

The part carries a DIN EN 81346-2 reference code Q. The SIRIUS series is generally UL/CSA/CE certified, though specific agency marks are not listed in this record. Standard Siemens declaration of conformity and RoHS/REACH documentation is available upon request through the supply channel.